Location grips on a plumbing line segment
Location grips on a plumbing fitting
Location grips on an MvPart (a pump)
If the plumbing line segment is not connected to another object, you can change both its length and angle
using the Start grip or End grip.
The Start and End grips enable you to change the XY location of the start point or end point of the segment.
This is useful when you are initially designing runs because you can easily connect a segment to an existing
run.
If the part or plumbing line segment is connected to other objects, you must specify whether you want to
maintain their connectivity when you move the part.
Rotate Grips
You can use the Rotate grip
to rotate plumbing in-line parts, fittings, and takeoffs 180 or 90 degrees in
the direction indicated by the grip.