First routing solution
Second routing solution
TIP
If you are routing
on page 251, you can increase the software response time by doing the
following: specify No for Use fitting tolerance, specify the desired angle for Bend angle, and specify the preferred
Branch fitting. This helps the software generate more specific auto-layout routing solutions based on specific
settings.
Constrained Layout Solutions
AutoCAD MEP can generate constrained layout solutions. Constrained layout intelligently connects one
pipe object to another in
on page 256 (gravity-based) or non-sloped (pressure-based) pipe systems,
even if the 2 pipe segments are at different slopes or elevations. AutoCAD MEP achieves constrained layout
based on the following guidelines:
■
Horizontal routing solutions are supported when you connect 2 objects at different elevations.
■
New vertical segments that are added to a pipe run remain vertical to the UCS (current user coordinate
system).
■
If you select Yes for Use fitting tolerance on the
on page 286 and the joint supports
angle of deflection, the angle of deflection is distributed equally between the female connectors on the
pipe object. For example, if you set a slope value of 10 degrees on the Properties palette, and the pipe
object has 2 female connectors, then each connector can have an
on page 267 of 5
degrees each. The value cannot exceed the maximum allowable angle of deflection (AoD) that is stored
in the content for the part.
Auto Layout | 255
Summary of Contents for 235B1-05A761-1301 - AutoCAD MEP 2010
Page 1: ...AutoCAD MEP 2010 User s Guide March 2009 ...
Page 22: ...4 ...
Page 86: ...68 ...
Page 146: ...128 ...
Page 180: ...162 ...
Page 242: ...Modifying the elevation of a duct 224 Chapter 6 Drawing HVAC Systems ...
Page 264: ...246 ...
Page 480: ...462 ...
Page 534: ...516 ...
Page 616: ...598 ...
Page 658: ...640 ...
Page 788: ...770 ...
Page 802: ...784 ...
Page 820: ...802 ...
Page 878: ...860 ...