INSTRUCTIONS VELOSE-80A
Page 13
SLIDING GATE OPENER
1. Function Adjustment
(Follow the steps below)
After you done” Total Timer Adjustment”, we recommend not to change the setting for
A0~ B0. If you prefer to change, please refer to following steps.
Step 1 : press “f” button ,the indicator will show “C8”
Step 2 : press “+” button, it’ll show in turn
“C9,D0,D1,D2,A1,A2,A3,A4,A5 PRESS “-“ Button, it’ll show reversely
Step 3 : press “F” button after choose the item, the indicator will show numbers
Step 4 : press “+” or “_” button to select levels
Step 5 : press “Enter” button to confirm
Step 6 : press “F” button for return to previous configuration menu.
Item
Name / Explanation
Setting
Range
Default
Setting
RE
A0
Intermediate Stop Function with slow speed.
This refers to the sensitivity of gates when
meeting
obstacles
during
slow
speed
operation.
0~99
20
Lower setting means
the gates will be more
sensitive to stopping.
A1
Intermediate Stop Function with high speed.
This refers to the sensitivity of gates when
meeting
obstacles
during
high
speed
operation.
0~99
35
Higher setting means
the gates are not as
sensitive to stopping
on hitting an obstacle.
A2
Total Timer/distance setting when opening
gate
0~99
67
Decimal/single digits
(shown on LED display)
A3
07
Thousands/hundreds
digits (shown on LED
display)
A4
Total Timer/distance setting when closing
gate
0-99
67
Decimal/single digits
(shown on LED display)
A5
07
Thousands/hundreds
digits (shown on LED
display)
A6
Force of opening and closing - slow speed.
Force adjustment for low speed operating
during open and close.
0~99
42
.