Copyright © 2005 Automated Equipment LLC All Rights Reserved
15
NON-SCHEDULED MAINTENANCE
This section gives the procedures for several repairs
that do not require special tools.
REPLACEMENT OF WATER TRAP BOWL
Parts: Water trap bowl
1.
Turn the main Power Switch for the Arch Fry
Dispenser to the OFF position.
2.
Remove the Fry Baskets from the Arch Fry
Dispenser.
3.
Disconnect the Air Line from the back of the
Arch Fry Dispenser by grasping the collar on the
Quick Coupler and pulling back until it releases from
the Coupler Nipple.
CAUTION:
Failure to remove the system air
pressure could result in injury.
4.
Remove the lower back panel of the Arch Fry
Dispenser.
5.
Make sure the air pressure gauge reads 0 PSI
on the regulator inside the Arch Fry Dispenser.
6.
Pull down on the thumb clip that locks the
water trap bowl and by turning it to the LEFT. The
plastic bowl will come off by pulling down on the guard.
7.
Remove the old bowl. Insert the new water
trap bowl into the metal guard. Ensure that the O-ring
is located on TOP of the bowl.
8.
Replace the guard and bowl assembly on the
Filter/Regulator unit by pushing up and turning it to the
RIGHT.
CAUTION
: Hand-tighten only!
9.
Reconnect the main Air Line to the Quick
Coupler. Check for leaks. Replace the outside cover.
ADJUSTING FILTER/REGULATOR AIR
PRESSURE SETTING
1.
Turn the Arch Fry Dispenser Power Switch to
the OFF position.
2.
Disconnect the electrical power plug from the
wall outlet.
3.
Remove the lower back panel of the Arch Fry
Dispenser.
4.
Ensure at least 80 PSI (5.4 bar) is being
supplied to the Filter/Regulator.
5.
Pull DOWN on the black adjustment knob
located below the air pressure gauge.
6.
Turn the knob COUNTERCLOCKWISE to
decrease air pressure and CLOCKWISE to increase
air pressure. Adjust the air pressure to 80 PSI
(indicated on the gauge) by turning the knob.
7.
Push UP on the knob to lock it in place.
8.
Replace the lower rear panel.
9.
Plug the Power Cord into the wall outlet.
10.
Move the Arch Fry Dispenser back into
position.
11.
Turn the ARCH Fry Dispenser Power Switch
to the ON position.
RESETTING THE DRUM MOTOR CIRCUIT
BREAKER.
WARNING
: ELECTRICAL SHOCK HAZARD!
Keep hands and tools away from all electrical
components.
1.
Turn the Arch Fry Dispenser main Power
Switch to the OFF position.
2.
Unplug the ARCH Fry System from the wall
outlet.
3.
Remove the LOWER BACK PANEL of the
Arch Fry Dispenser.
4.
Locate the Circuit Breaker. If the Start/Reset
Button on the breaker has popped out (tripped,
showing white), reset the breaker by pushing the
BLACK button IN.
5.
Re-install the LOWER BACK PANEL.
6.
Verify that the Dispenser Drum and Fry
Diverter are installed properly.
7.
Plug the Power Cord into the wall outlet.
8.
Turn the main Power Switch to the ON
position.