Revised 4/3/00 • MX400

5

© 2000 Automated Logic Corporation

Production Date

To determine when a module was
manufactured, check the module status
report for the module in SuperVision. Refer to
the

SuperVision User’s Guide

for more

information about the module status report.

A sticker on the back of the module also
shows the date the module was
manufactured. The first three characters on
the sticker indicate the type of module. The
next three characters show the year, month,
and week of manufacture. (The month digit is
in hexadecimal.)

Summary of Contents for MX400

Page 1: ... and Alert are registered trademarks of Automated Logic Corporation InterOp is a trademark of Automated Logic Corporation BACnet is a registered trademark of ASHRAE All other brand and product names are trademarked by their respective companies Technical Instructions MX400 Using the MX400 2 Specifications 2 Mounting 3 Addressing 3 Power Wiring 3 Digital Outputs 3 Channel Numbers 4 Troubleshooting ...

Page 2: ...ea is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Specifications Power 24VAC 10 50 60Hz 24VAC 10 60Hz for UUKL Smoke Control Systems 8VA power consumption single Class 2 source only 100VA or less Digital Outputs four digital outputs relay contacts rated at 3A resistive 24VAC Configurable as normally open or normally cl...

Page 3: ... properly 1 Turn the module s power off This prevents the module from being powered up before the proper voltage is verified 2 Make sure the 24VAC power source is off 3 Connect the power wires to the module s power terminals labeled Ground and 24VAC see Figure 1 on page 2 for location 4 Apply power to the transformer 5 Make sure that 24VAC is present at the module s power input terminals 6 Set the...

Page 4: ...ooting LEDs The MX400 module has several LED indicators to show the status of certain functions Power lights when power is being supplied to the module Run flashes to indicate a normal condition Expander Comm flashes to indicate expansion bus communications are valid Digital Output Status lights when the digital output is activated Protection The MX400 module is protected by internal solid state P...

Page 5: ... in SuperVision Refer to the SuperVision User s Guide for more information about the module status report A sticker on the back of the module also shows the date the module was manufactured The first three characters on the sticker indicate the type of module The next three characters show the year month and week of manufacture The month digit is in hexadecimal ...