background image

AUTOMATIC FILTERS, INC.

Tekleen

2672 S. LA CIENEGA BLVD.

LOS ANGELES, CA 90034

310 839 2828  800 336 1942

FAX 310 839 6878

www.tekleen.com

info@tekleen.com

CSB

USERS’ MANUAL

Summary of Contents for Tekleen CSB

Page 1: ...AUTOMATIC FILTERS INC Tekleen 2672 S LA CIENEGA BLVD LOS ANGELES CA 90034 310 839 2828 800 336 1942 FAX 310 839 6878 www tekleen com info tekleen com CSB USERS MANUAL ...

Page 2: ...ration 3 4 Technical Data 5 6 Installation 7 8 Filter Assembly 9 11 Periodic Checks 12 Filter Parts 13 14 Filter Controls 15 20 ALL RIGHTS RESERVED THIS MANUAL AND THE INFORMATION CONTAINED ARE NOT ALLOWED TO BE USED WITHOUT WRITTEN PERMISSION FROM AUTOMATIC FILTERS INC ...

Page 3: ...wide family of filters produced and supplied by Automatic filters Inc for industrial municipal water sewage systems and all types of irrigation applications All products manufactured by Automatic Filters Inc are easy to install use and service and don t require special skills to operate them We would like to wish you many years of satisfied service ...

Page 4: ...r enables high quality filtration at filtering degrees of 200 4000 micron from different types of fluid sources such as sewage reservoirs rivers lakes and wells The CSB filter contains the following parts 1 Inlet 4 Flushing Valve HYD or Electric 2 Screen 5 Electric Motor 3 Brush 6 Outlet Figure 1 Filter Assembly ...

Page 5: ...essure P reaches the preset value on the differential pressure indicator or the dwell time between flushing passed The controller transmits a signal for a 10 second flushing cycle The flushing valve 4 opens pressure is released from the inner side of the fine screen 2 the electric motor 5 simultaneously rotates the brushes 3 around its axis The brushes wipe all the dirt and efficiently clean the e...

Page 6: ...using materials carbon steel coated with baked on epoxy or stainless steel General Technical Data Filter Model M3 h GPM Screen Area Sq ft CSB 4 100 400 5 CSB 6 200 800 5 CSB 8 300 1 200 5 CSB 10 450 1 800 7 CSB 12 650 2 600 11 CSB 14 1 000 4 000 12 5 CSB 16 1 500 6 000 16 L 90O Connections IL Inline connections Flow rate data are for high quality water at filtration grade of 200 micron Flushing fl...

Page 7: ... 5 Pressure Loss At 200 Micron ...

Page 8: ...npipe to the hydraulic flushing valve outlet opening at least 80 mm or 3 diameter and no longer then 10m Confirm that water runs freely out of the drainpipe 4 Position the control panel in such a way as to be protected against humidity and solar radiation 5 Connect the control panel to the power source 6 Check that all connections are properly secured 7 Check that all bolts and nuts on filter peri...

Page 9: ...e flushing valve opens and closes after 10 seconds 6 Perform a flushing cycle by pressing the MANUAL FLUSH switches at the control panel 7 Perform continues flushing by disconnecting the high pressure tube from the differential pressure indicator closing of the electrical circuit second flushing will start without a delay Re connect the high pressure tube 8 When the filter is clean verify that the...

Page 10: ...ssembly with the brush assembly into the filter housing assembly 10 Verify that the straight side of the body seal fits into the groove located in the cover 11 Put the cover into its place on the filter Take care that the motor s axis housing is slide on the brush axis install nuts and washers 12 Set the main switch at the control panel to 1 position 13 Open the inlet and outlet line valves 14 Per...

Page 11: ... 9 Figure 4 Figure 5 ...

Page 12: ... 10 Figure 6 Brush Removal Installation Figure 7 Fine Screen Assembly Removal Installation ...

Page 13: ...als condition Lubricate with silicon grease 3 Remove the brush according to brush Removal Installation and check the brushes height If defective adjust or replace with a new one 2 Check condition of the bearings replace if damaged or deformed 3 Check existence of grease on the motor axis 4 Check the filter housing for paint damage and corrosion If required clean area with sandpaper and apply a thi...

Page 14: ... 12 ...

Page 15: ...en Handle 12 Screen O ring 13 Fine Screen Lower Section 14 Fine Screen Middle Section 15 Fine Screen Upper Section 16 Upper Screen Handle 17 Brush Assembly Axis 18 Brush Unit Tightening Screw 19 Brush Unit 20 U Ring body seal 21 Body Cover 22 2 Connecting Nipple 23 2 Flushing Valve 24 Seal Housing Nut 25 Special Rope Seal 26 Seal Tightening Nut 27 Motor Adaptor 28 Spinning Shaft 29 Shaft Splint 30...

Page 16: ...rols filter motor 5 TR1 Multi voltage 24Vac transformer 6 TP Sets Differential pressure switch sense time 7 TF Sets the flushing time 8 TD Sets the interval time between flushes C TERMINAL CONNECTIONS TB 1 4 Line supply 380 480Vac GND 3 phase 50 60Hz inlets TB 5 8 380 480Vac GND 3 phase 50 60Hz M1 motor supply voltage outlets TB 9 10 SV Flushing solenoid outlets 24V 10W COIL TB 11 12 DP Differenti...

Page 17: ...nchronization must be carried out as follows a Switch the MAIN switch to ON 1 position and Verify that L1 ON indicator lights b Press pushbutton MANUAL FLUSH momentarily and Verify that L2 FLUSH indicator lights and the motor activated simultaneously Check the motor axis rotation Which drives the filter dirt collector The rotation must be at the same arrow label direction If not switch the MAIN sw...

Page 18: ...essure signal for 5 sec set by TP timer c Elapsed time of TD timer IF ENABLED BY SET INLETS NOTE That TD can be set in the range of 1 100HR CROUZET MAR1 ON DELAY INDUSTRIAL TIMER REVIEW 1 Operation The MAR1 is a standard on delay industrial timer ranging from 0 1 second to 100 hours on delay On connecting the supply voltage 24Vdc 24 240Vac to A1 A2 terminals the timer will begin the set on delay t...

Page 19: ...time range multiply the time set scale by 6 Example On delay of 18 seconds is required a Set the time range knob to 6 60s position b Set the time set knob to 3 3x6 18 seconds 3 State indicator Un signals a No light The timer is in off state No supply on A1 A2 terminals b Blinking light The timer is counting On delay c Steady light The timer reached the time set Internal relay energized ...

Page 20: ... 18 ...

Page 21: ... 19 ...

Page 22: ...l damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or property loss of use of the products loss of goodwill loss of profits or any other contingent liabilities of any kind or character alleged to be the cause of loss or damage to the purchaser This warranty does not cover damage or failure caused by misuse abuse or negligence...