User operating instructions

6.9 - WARNINGS

HOW TO AVOID CORROSION IN THE 
WOOD STORAGE COMPARTMENT

The use of wood with a high moisture content (higher 
than about 25%) and/or loads not proportioned to 
the system’s heat request (long OFF periods with the 
wood storage full) can cause considerable condensate 
formation in the storage compartment’s internal wall.
Check the steel walls of the upper wood storage once 
a week.
They must be covered by a slight layer of dry tar, opaque 
coloured, with bubbles tending to break and fall off. 
On the other hand, the tar will have a glossy, runny 
appearance and liquid will appear if it is removed with 
a poker: accordingly, it is necessary to use wood that is 
less damp and/or reduce the amount of loaded wood.
If, despite these interventions, the tar does not dry, you 
must inform the local After-Sales Service.
T h e   c o n d e n s a t e   i n s i d e   t h e   f i re w o o d   s t o r a g e 
compartment causes the steel sheets to corrode.
Corrosion is not covered by the warranty, as it is caused 
by improper use of the boiler (wet wood, excessive 
loading, etc.).

CORROSION OF THE FLUE CIRCUIT

Flue gas is rich in water vapour, due to combustion and 
the use of wood which retains water.
If the fl ue gas comes into contact with relatively cold 
surfaces (having a temperature below 60 - 70 °C), the 
water vapour condensates and, combining with other 
combustion products, originates corrosion of the 
metallic parts.
Check daily whether there are signs of flue gas 
condensation (black liquid on the fl oor and behind the 
boiler). In this case you must use wood with a lower 
moisture content; check that the recirculation pump is 
working correctly and the fl ue gas temperature at partial 

load, and increase the working temperature. In order to 
control the room temperature, it is therefore necessary 
to install a mixer valve. 

The corrosion caused by the 

fl ue gas condensation is not covered by the warranty, 
as it is caused by the wood’s moisture content and 
the way the boiler is used.

WARNINGS DURING USE

Every time the air is adjusted, wait 5-10 minutes before 
proceeding with the next adjustment

. When you have 

established the best air adjustment, at the end of the 
day, check the surfaces of the combustion chamber and 
the door insulation as they should be white.
There must be only a few unburnt embers in the ash 
deposited in the cradle. If there is too much primary 
air, there will be ember and small pieces of coal in the 
ashes, the fl ame will be quick, dry, a cooler colour and 
will make more noise, with excessive power (chap. 6.7).
If the primary air is insuffi cient, the fl ame will be slow, 
small, it will not caress the lower cradle, dragging few 
ashes and the heat output will be insuffi cient.
If the flame is dark orange, the secondary air is 
insuffi cient and the surfaces of the combustion chamber 
will not be white; if it is small and blue, there is too much 
secondary air.
Always open the loading door and the internal anti-
smoke door slowly.
If despite this warning there are blowbacks, you must 
use large logs which are a bit moister, make sure the 
boiler is not stopped for too long (reduce primary air - 
par. 6.7) and check whether any grates are broken. Also 
check that foreign objects (nails, metal pieces) have not 
obstructed the refractory burner hole.

6.10 - SUMMER MODE

The use of the boiler in summer only for the production 
of domestic hot water is not advised, unless you follow 
these rules meticulously:
1) Use very dry wood.
2) Load a small amount of wood in the boiler 2 or 3 

times a day as needed. 

Important.

It is very wrong to load the boiler completely, providing 
it with long self-suffi ciency (for example 24 hours). This 
way the boiler (with the fan stopped) would produce 
much acid condensation corroding the wood storage 
compartment.

Summary of Contents for Firex 34

Page 1: ...Biomass Wood Fired Water Heaters Operating Manual Firex34 55kW ...

Page 2: ...purposes also includes careful compliance with the instructions in this manual 3 WATER TREATMENT The hardness of the feed water conditions the frequency at which the domestic hot water producer must be cleaned If the water has a hardness greater than 15 f we recommend using water softeners chosen according to the characteristics of the water We recommend checking and cleaning any installed domesti...

Page 3: ...LLATION MAINTENANCE TECHNICIAN 5 SAFETY WARNINGS ATTENTION The appliance must be installed adjusted and maintained by professionally qualified personnel in compliance with standards and provisions in force Incorrect installation can cause damage to persons animals and objects for which the manufacturer cannot be held responsible DANGER NEVER attempt performing maintenance or repairs on the boiler ...

Page 4: ...t off With the switch at the boiler is powered electrically green indicator light on and is set up for operation The recirculation pump works Operating mode selection keys Using switch 13 it is possible to power off the system pump boiler load With the switch on 0 the system pump is not powered electrically When the switch is on the system pump is not electrically powered 32Working thermostat 41Ge...

Page 5: ...imum temperature approx 65 C within the required amount of time the fan and recirculation pump will switch off The panel is powered but the boiler is not running Light the wood once again Heating temperature control It is possible to control the temperature of the FIREX boiler system water by turning the knob pos 32 clockwise to raise it and counter clockwise to lower it Temperature is adjusted be...

Page 6: ...normally closed when the loading door is closed Opening the loading door causes the fan to start up automatically In this way the smoke accumulated in the wood storage is suctioned and sent to the chimney directly The bypass in conclusion allows the smoke to be discharged to the chimney without escaping from the loading door when loading the wood or during lighting Complete decommissioning When th...

Page 7: ... together with the moisture content contribute to determine the boiler s output Small pieces with a length however conforming to indications indicated hereby are more easily flammable and therefore have the tendency to increase the boiler s output and therefore to reduce its autonomy Moreover they fall with greater facility in the lower chamber reducing the risk of the formation of bridges The so ...

Page 8: ... LOADING Before loading wood once again consume the previous one as much as possible It can be reloaded when the bed of embers in the firewood compartment will be reduced to a thickness of about 5 cm Open the loading door and the internal anti smoke door slowly It is necessary to use wood logs with the length stated in the previous paragraph Place the new wood logs as described above USEFUL TIPS L...

Page 9: ...G SEALS During the initial start up check the tightness of the smoke circuit and the connection to the chimney If there is any noticeable smoke leakage alert the installer and or our After Sales Service If there is any noticeable aspiration of air through the door seals tighten the handle with greater force Make sure the working thermostat is in good running order Te 32 at full power until it stop...

Page 10: ...erefore necessary to install a mixer valve The corrosion caused by the flue gas condensation is not covered by the warranty as it is caused by the wood s moisture content and the way the boiler is used WARNINGS DURING USE Every time the air is adjusted wait 5 10 minutes before proceeding with the next adjustment When you have established the best air adjustment at the end of the day check the surf...

Page 11: ...he firewood storage compartment Use the supplied brush to clean the triangular ducts in the furnace Remove the ashes contained in the smoke chamber from the side doors using a scraper Make sure that the slots in the grate are not obstructed if they are clear them up using the poker If the boiler continues to operate badly even after having cleaned it as described above the cause can be attributed ...

Page 12: ...m When opening the loading door there are blowbacks and smoke escape Remedy Open slowly Use damper wood make sure that the boiler has not have prolonged downtime see chap 6 9 Use larger logs Consume the previous load of wood before reload ing Problem The boiler does not reach the requested temperature The flame is small and there is too much air Inspecting the wood storage the formation of log bri...

Reviews: