Instructions for the installer
6.10 - THERMOSTAT ADJUSTMENT
WOOD FIRED BOILER
The boiler’s adjustment thermostat must be set
to the desired temperature (the adjustment
range,
limited by stoppers that must not be removed,
varies from 75° to 85°C).
To adjust the boiler’s flow temperature to the heating system it
is necessary to foresee the installation of a 3 or 4 way mixing
valve.
If this mixing valve is not installed the guarantee will be
void.
The manual reset safety thermostat, pos. 31, complies to the
regulations in force.
At the start-up stage check if it has to be reset.
To do this unscrew the plastic protecting cap and press the
reset button; then replace the plastic cap.
If the boiler safety’s thermostat has to intervene frequently,
pos. 31, reduce the setting temperature of the working
thermostat (pos. 32 on the control panel).
If this problem is repeated, inform the local After Sales Service.
6.11 - SUMMER OPERATION
Use of the boiler in summer for the production
of only domestic hot water is not advised, unless
you follow these rules meticulously:
1) Use very dry wood
2) Do not load the boiler with too much wood,
load the boiler partially, 2 or 3 times per day
according to need.
6.12 - BURNER ADJUSTMENT ON
BACK- UP BOILER
The burner must be serviced exclusively by an
authorized service technician.
Important.
It is absolutely wrong to load the boiler
completely so as to gain very long working
periods (for
example 24 hours). Doing so the boiler (when
the fan is OFF) will produce a lot of acid
condensate
and corrode the fire box.