Servicing schedule
Components to check during annual servicing
Cast iron fire bars
Stainless steel grate
Fire bars mineral wool insulation
Primary and secondary air inlets
Soundness of the bypass disk
Integrity of the combustion chamber refractory bottom
Position of bottom stainless steel container
Refractory insulation integrity in upper and lower doors
Integrity of doors seals
Correct operation of the loading door microswitch
Cleaning the fan blades
Fan noise
Cleaning the flue circuit (on the rear side of boiler)
If necessary replace
If necessary replace
If necessary replace
If necessary clean them
If necessary adjust it
If necessary repair it using the refractory kit (see spare
parts list)
If necessary re-position it
If necessary repair and/or replace the doors
If necessary replace them
If necessary adjust it
If necessary clean them
If necessary replace the fan
If necessary clean it