7
Technical features and dimensions
A
F
30
B
T1
T4
T6
T4
T3
T5
T1
T4
T3
T2-T8
E
1
7
8
3
2
4
9
D
C
G
T2
T8
T7
6
5
2.2 - DIMENSIONS AND
WATER CONNECTIONS
fig. 1
1.
Control panel
2.
Primary air adjustment
3.
Secondary air adjustment
4.
Flame sight control
5.
Cleaning door
6.
Rear smoke chamber
7.
Loading door
8.
Fan
9.
Bottom inspection and cleaning door
T1. Central Heating flow
T2. Central Heating return
T3. Chimney connection
T4. Safety heat exchanger connections
T5. Bulb holder connection for heat discharge
valve
T6. Bulb holder for safety thermostat
T7. Bulb holder for thermometer and high limit
and minimum working thermostat,
T8. Boiler drainage
* Output obtained with good quality wood with a 15% .moisture content.
** Pressure losses for a flow rate corresponding to 15 K Delta T.
MODELS
GASOGEN
G3 25 2S
GASOGEN
G3 40 2S
GASOGEN
G3 50 2S
(kW)
15
23
29
AVERAGE OUTPUT
MINIMUM OUTPUT
MAXIMUM USEFUL OUTPUT*
(kW)
26
37
47
(kW)
29
47
58
MAXIMUM OUPUT
(kW)
34
55
69
DIMENSIONS:
A
B
C
D
E
F
G
560
700
655
700
655
900
1225
1355
190
315
190
315
245
1030
1355
190
315
245
245
1140
1140
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
CONNECTIONS T1 - T2
T3
T4
T5 - T6 - T7 - T8
UNI ISO 7/1
(Ø mm)
UNI ISO 7/1
Rp 1¼
150
R ½
Rp ½
Rp 1½
200
R ½
Rp ½
Rp 1½
200
R ½
Rp ½
BOILER WATER CONTENT
WATER SIDE PRESSURE DROP**
SMOKE SIDE PRESSURE DROP
MAX. WORKING PRESSURE
FIRE BOX STORAGE VOLUME
FIRE BOX DIMENSIONS
WEIGHT
WOOD LOGS LENGTH
(m c.a.)
(l)
90
0,10
110
0,08
140
0,12
0,6
0,4
0,3
(mm c.a.)
(bar)
(l)
(mm)
(kg)
3
95
290x340
386
3
135
350x440
475
3
185
350x440
593
(cm)
50
50
70
GASOGEN
G3 65 2S
41
64
76
88
755
955
1405
190
315
245
1180
Rp 2
220
R ¾
Rp ½
170
0,06
0,3
3
235
340x520
630
70
GASOGEN
G3 80 2S
52
76
93
109
755
1255
1405
190
315
245
1180
Rp 2
220
R ¾
Rp ½
220
0,10
0,5
3
325
340x520
850
100
UNI ISO 7/1