Food Driver Board
The Food Driver Board is located on the front face of the Relay Box for the compressor assembly. This board controls the
function of all the refrigeration components along with providing the circuits for the vend motors and the baffle delivery
door. There are also two jumpers for default settings of this board.These jumpers are a set of three pins which will have
only two pins connected at any one time. The connection between the two pins is made by a small black cap, which
slides over the pins in use. The blacl; caps are identical, and should not be removed from the board for any reason.
Cabinet Selection Jumper
The position of this jumper identifies which cabinet is named CAB1 (Cabinet 1), or CAB2 (Cabinet 2).These are
abbreviated on the FDB board cover decal (pictured below) as
C1
and
C2
Cabinet 1 will contain the selections 110
through 157, and Cabinet 2 will contain the selections 210 through 257.AII machines are shipped with this jumper
installed on CAB 1.This jumper should be changed only if you are connecting a second cabinet to a 310 Control Module
or a 120 Snack.
Temperature Control Jumper
The second jumper on the board controls the default setting for the temperature in the event the FDB looses
communication with the LCB. This will hold the cabinet temperature at the setting indicated by the jumper. A jumper set at
“
R
” will hold the temperature at 36°F (2°C), and a jumper set at “
F
” will hold the temperature at -15°F (-26°C). If you
change the temperature in the
SET TEMPS
menu item, you must also change the position of the jumper to the
corresponding position.The position of this jumper can be verified through the hole in the board cover.
Cabinet Selection Jumper
Temperature Control Jumper
F
R
Summary of Contents for 310
Page 45: ...section 5 parts This Page Intentionally Left Blank ...
Page 46: ...5 01 310 control module cabinet ...
Page 48: ...5 03 310 control module door ...
Page 50: ...5 05 310 swing panel ...
Page 52: ...5 07 310 board and power box assembly 21 24 ...
Page 54: ...5 09 310 power supply box ...
Page 56: ...5 11 320 inside door ...
Page 58: ...5 13 320 thermal window 4 6 2 8 5 12 10 11 14 1 15 13 7 16 3 17 18 ...
Page 64: ...5 19 320 baffle door assembly 8 7 6 6 4 3 5 2 1 10 9 11 ...
Page 66: ...5 21 320 baffle motor assembly 7 8 9 6 5 20 5 19 12 3 2 1 4 18 17 15 16 14 13 11 10 ...
Page 68: ...5 23 320 refrigeration assembly and components 7 6 5 12 10 13 1 4 3 11 8 ...
Page 72: ...5 27 320 junction box side wall mount 14 21 9 2 4 1 17 7 20 6 3 8 5 19 15 ...
Page 74: ...5 29 320 8 select spiral shelf 18 16 17 10 9 11 16 13 14 12 11 9 10 1 15 8 3 2 7 5 4 6 ...
Page 76: ...5 31 320 conveyor shelf 7 4 5 14 13 17 12 10 8 9 6 11 16 2 16 3 1 15 ...
Page 78: ...5 33 320 conveyor module 1 5 4 6 13 14 16 8 7 11 12 17 3 12 20 9 15 2 8 18 19 10 16 ...
Page 80: ...5 35 310 trim Top Trim or Trim Insert Trim Outside Vertical Trim Lower Horizontal Bottom Trim ...
Page 82: ...5 37 310 panels Lower Panel Upper Panel Top Insert ...
Page 89: ...6 01 trouble shooting chart ...
Page 90: ...6 02 trouble shooting chart ...
Page 91: ...6 03 trouble shooting chart ...
Page 94: ...6 06 electrical connections ...
Page 95: ...6 07 electrical connections P7 Default Refrigeration Jumper HI Refrigerated LO Frozen ...
Page 96: ...notes ...
Page 97: ......
Page 98: ...55 ...
Page 99: ......
Page 100: ...55 ...