background image

Commissioning

Position the gate halfway and tighten knurled knob at back of slider, very firmly, by hand so gate will
drive.

Power up board and with gate in the half way position, press transmitter or manual control switch so
operator drives gate.

The first pulse will always open gate, green LED will flash (top right hand corner) if it does not, then
reverse 2 of the motor wires.

Check which limit switch stops gate in each direction and adjust cams so gate will stop in the fully
open and closed positions.

Limit switches should not switch off the gates too soon (before reaching the stops) and conversely not
too late, so the torque limiter is operating.

Tighten torque limiter knurled knob.

Set open & closed travel time.

Check that all safety devices work as designed and the electromagnetic lock holds the gate firmly
closed (if fitted).

Install cover using screws provided in the front and sides to hold cover firm.

Provide full details to the owner concerning the operation and relevant maintenance and disconnect

details.

4. M

A NU A L

R

EL E ASE

I

NS TR UC TION S

Should the power fail or for some other reason the gate does not operate in the normal motorised
manner, manual disconnection can be achieved by:-

Turn power off to the control box and isolate.

By using the key, unlock the door on the back of the cover.

Turn the large knob anticlockwise which will release the drive

Manually slide open the gate.

Summary of Contents for 750L I Range

Page 1: ... components Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components April 2010 N14870 Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components ...

Page 2: ...the gate frame keeping 1mm 2mm clearance between the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freely over the pinion wheel any tights spots should be corrected by adjusting the rack height Check the operator is firmly bolted down to the concrete pad E...

Page 3: ...he gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening speed closing speed and ramp times Automation settings operating modes are able to be adjusted via the CB6 board refer to manual for further instructions Once Inverter settings are appropriately set p...

Page 4: ...tion 3 Installation Page 6 10 Electrical Cabling Mechanical Installation Electrical Connections CB6 Control Board Variable Speed Drive Unit Commissioning Section 4 Manual Release Instructions Page 10 Section 5 Maintenance Page 11 Section 6 Warranty Page 12 Annexure Control Board Layout for Inverter Controls Schematic Wiring Diagram ...

Page 5: ... install the automation equ ically to open and close sliding gates or doors and sh read through this installation manual ols are in new condition and have not been damaged i ociated support posts and walls to protect against shea aps which could cause serious injury or death Take in nding environment structure has the necessary strength and rigidity to su ng and closing gate motion riate Photo Ele...

Page 6: ...g the previous sections in this manual and having checked for suitable installation proceed as follows Electrical Cabling A suitably rated Isolator and 240v power supply should be available near to where the gate operator is to be mounted The following diagrams will provide measurements for the positioning of conduits and the appropriate position for mounting the operator whether a GDS 550 450LI o...

Page 7: ... and operator in approximate mounting location Use the rack to locate the operator the correct distance away from the gate rail finer adjustment can be made after Dynabolt or chemical anchor the bottom mounting plate to the concrete mounting pad using 12 x 100mm fixings Unscrew anticlockwise the manual disconnect knurled knob so the drive gear free wheels Fix the rack to the gate rail ensuring the...

Page 8: ...ng associated with it use an IM 1 module to isolate it from the control board s input The IM 1 is available from the manufacturer Powering Accessories Accessories which require a 24v AC supply can be powered from the transformer output used to power the control board via the isolated 24v AC supply which is connected to the DIN rail terminals as labelled However the transformer s current capacity m...

Page 9: ...inal will only open the door gate The input also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output controls second motor ON The M2 output controls status lights Position 6 P E STOPS CLOSE CYCLE OFF Activating the P E input while motors are closing causes the ...

Page 10: ...ing times Note when setting the OPEN and CLOSE cycle times when limit switches are used release the push button a few seconds after the limit switch cuts motor power This allows for the motors to slow down over the life of the operators without the need to adjust again Variable Speed Drive Unit The variable speed drive unit will ramp up the speed of the operator and then ramp down prior to closing...

Page 11: ...nversely not too late so the torque limiter is operating Tighten torque limiter knurled knob Set open closed travel time Check that all safety devices work as designed and the electromagnetic lock holds the gate firmly closed if fitted Install cover using screws provided in the front and sides to hold cover firm Provide full details to the owner concerning the operation and relevant maintenance an...

Page 12: ...ical connections tig Limit Switches operate in ap External safety devices work Electromagnetic lock if fitte Gearbox self locking i e sea General operation i e speed Comments Service performed by S ult in injury or death and or damage to property and eq formed on the operator and gate are as follows cycles a day each month 100 150 cycles a day every 2 month 50 99 cycles a day every 4 months 20 49 ...

Page 13: ... in the following circumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not authorised to do so iv In respect of loss or damage caused by rough treatment v If the product is not used and maintained in accordance with instructions or recommendations listed ...

Page 14: ...Single Controls Dual Controls ...

Page 15: ...7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Control Input Connector 10 Open Stop Close Control Input 23 Inp ut Status L E Ds 11 Close Control Input 24 Stop Input Jumper 12 Stop Control Input 25 Open Input Jumper 13 Open Control Input 26 PE Beam Input...

Page 16: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Reviews: