Commissioning
Position the gate halfway and tighten knurled knob at back of slider, very firmly, by hand so gate will
drive.
Power up board and with gate in the half way position, press transmitter or manual control switch so
operator drives gate.
The first pulse will always open gate, green LED will flash (top right hand corner) if it does not, then
reverse 2 of the motor wires.
Check which limit switch stops gate in each direction and adjust cams so gate will stop in the fully
open and closed positions.
Limit switches should not switch off the gates too soon (before reaching the stops) and conversely not
too late, so the torque limiter is operating.
Tighten torque limiter knurled knob.
Set open & closed travel time.
Check that all safety devices work as designed and the electromagnetic lock holds the gate firmly
closed (if fitted).
Install cover using screws provided in the front and sides to hold cover firm.
Provide full details to the owner concerning the operation and relevant maintenance and disconnect
details.
4. M
A NU A L
R
EL E ASE
I
NS TR UC TION S
Should the power fail or for some other reason the gate does not operate in the normal motorised
manner, manual disconnection can be achieved by:-
Turn power off to the control box and isolate.
By using the key, unlock the door on the back of the cover.
Turn the large knob anticlockwise which will release the drive
Manually slide open the gate.
Summary of Contents for 750L I Range
Page 14: ...Single Controls Dual Controls ...