background image

14

TECHNICAL FEATURES

Power supply

The electric power is supplied to the electronic card and the motors by means of an electric transformer fitted with a protection fuse. The

appliance may be connected to an optional backup battery (12Vdc/ 7 Ah) for the automation system to work in case of absence of mains

power supply.

Radio Receiver

The electronic unit contains a two-channel radio receiver allowing remote control of the gate by means of the radio transmitter. The radio

receiver channel 1 acts as

Start

control and channel 2 acts as

Pedestrian start

. The radio receiver operates with a self-learning logic and

can store up to 50 different codes from the remote controls. Each code may be addressed on the desired channel (start or pedestrian start).

The memory content is preserved in absence of power supply. The memory contents may be erased (total cancellation). In alternative the

electronic unit is equipped for the optional connection of an accessory radio receiver card (J6 connector). The channel 1 of the radio

receiver card ends with a non-polarized electric contact (relay) directly connected to the

start

input. The channel 2 of the radio receiver

card ends with a non-polarized electric contact (relay) directly connected to the

2nd radio channel

output.

Work Time

The motors’ work time is controlled by two independent digital timers. If any command interrupts the wing’s travel before its end, the timer

stops and the elapsed time is stored in memory. Therefore the unit can determine, with a fair approximation, the partial working time

necessary for the wing to end its travel.  For the automation system to work properly the work time value to be set must be slightly (approx.

5 sec.) above the wing’s actual work time. In this way the motor will stop even if the limit switch control has not operated. We recommend

to adjust the work time so that the wing starts to slow down at min. 50 cm. from the end of its travel. The stop of the wing depends by the

current consumed by the motor (Torque). During the normal speed phase, when the motor's current reaches the self-learned value, the

gate stops (both wings) in opening and then it reverses its motion for approx. 2 sec., while during the closure phase, the gate stops and

reverses its motion after approx. 1.5 sec. After the electric power is supplied to the electronic card (at installation), or after one absence of

power supply, when the Start push-button is pressed for the first time the gate performs an opening cycle.

Warning

: In case of absence of power supply the position of the gates will be lost (Timers reset) and the gates first command will perform

and opening manoeuvre.

Kickback / Extra-push

This procedure can be enabled or excluded. It is usually employed to help the electric lock insertion and release during bad weather

conditions (wind, etc.). The “

kickback

” procedure consists of a logic sequence operating the electric lock with a short closure phase

(approx 1 sec.) with the gate closed. The electric lock is released only after the wing has started its opening motion. The “

extra-push

procedure is enabled only during the closing slow-down phase near at the end of the wings’ travel. It consists of a short acceleration of

both wings (approx. 1 sec.) to help the electric lock’s insertion.

M1 delay at opening

The unit causes a fixed delay of approx. 2 seconds between the first wing’s (M2) and the second wing’s (M1) start during the gate’s

opening phase. This delay is imposed irrespective of the position from which the gate starts to open. This delay may be cancelled by

setting the

dip switch 5 =ON

.

Blinker

The electronic card supplies an on/off control (flashing light) to the lamp. The logic of the blinking allows displaying the gate’s operating.

Quick flashing light: signals the opening phase

Slow flashing light: signals the closing phase

Fixed light: signals that the gate is blocked in wait that the obstacle that covers the photocell or photostop to be removed.

The device supplies an on/off control (flashing light) to the lamp for approx. 1 sec. before the motors start (pre-alarm).

Important:

In case of absence of power supply, with the backup Battery connected to the card, the blinker flashes every 4 sec. (in opening

and closing cycle).

Summary of Contents for CTR50

Page 1: ...1 SWING GATE INSTALLATION MANUAL AUTOMATIC ...

Page 2: ... total width would be 4280mm But what happens if we add on a pedestrian gate to one side with hinges and clearance gap a fixed panel to the other side and two more 100mm posts GATES 2x1500 3000mm HINGES 2x30 60mm POSTS 2x100 200mm CLEARANCE 1x20 20mm PEDESTRAIN GATE 1x1000 1000mm HINGES 1x30 30mm PANEL CUT TO SUIT 1x1030 1030mm POSTS 2x100 200mm TOTAL WIDTH 5540mm Basic maths really So long as you...

Page 3: ...ckets four per post that you can use if you choose or you can fix directly through the post itself Whatever method you choose cut your post to length use adequate fasteners of correct size and suitable for the structure you are fitting to Touch up paint has been provided to color match any exposed brackets or fasteners if you wish CONCRETE IN Dig a hole of at least 300mm diameter and minimum 800mm...

Page 4: ...re are a number of ways to do this If you are very accurate you can measure and mark your gate fit the hinge bracket to the gate and then assemble all the parts You might find it easier however to assemble the hinge so it is complete on the post use blocks under your gate to lift and hold it at the correct height and then fix the hinges to the gate Using this method you can also use a 30mm packer ...

Page 5: ...cond Battery Charger Inbuilt 12 24V Maximum Thrust 1500 N Receiver Inbuilt or External Protection Level IP43 Limit Switches Yes No Duty Cycle 90 Pedestrian Input Yes NO Dimensions 670L x 90W x 185H Start Input Yes NO Stroke 30 CM Stop Input Yes NC Maximum Leaf 3 0 metres Photocell Input Two NC Maximum Leaf Weight 250 Kg Electric Lock Yes 12Vdc 1A Opening Time 16 Seconds Slow Speed Regulator Yes ...

Page 6: ...ructure and that there is no friction points in its movement Make sure that the gate s have both solid opening stops and solid closing stops GENERAL ORDER OF INSTALLATION To ensure a good installation of the gear motors ASA300 we suggest the following order of installation 1 Open the box and take out gear motor Inspect the contents and ensure all components are present 2 Make sure that the leaf of...

Page 7: ... D back one complete turn of 360 degrees Attach your gate bracket to the shaft end H and position on the gate taking careful note of your 12mm fall from the post bracket Fix your gate bracket at this position Using your manual override key put the gear motor into manual mode and gently move your gate and gear motor through the entire 90 degree arc to test the smoothness of your installation If you...

Page 8: ...pen input NO DL2 Power Supply LED START Open Stop Close input NO DL3 DL4 Open Input LED COM Common for STOP PHOTO inputs DL5 DL6 DL7 Stop Photo LED STOP Stop input NC DL8 DL9 Motor1 Limit Switch LED PHOTO Photocell Input NC DL10 DL11 Motor2 Limit Switch LED COM Photocell 2 common J3 Antenna Connector PHOTO Photocell 2 Input NC J2 External receiver connector FC1A Limit switch 1 opening input NC RV1...

Page 9: ... will be motor 2 which will open first if so programmed when dual gates overlap With single gates use motor 2 output only INSTALL YOUR INPUT LOOPS The only other wiring needed before testing your installation is to install a few loops into the NC or normally closed inputs Cut three short lengths 50mm of single core cable and strip the two ends Connect one end to the photo terminals and one end to ...

Page 10: ...setting of the work times Use your transmitter and drive the gate s to the fully open position Set the trimmer RV1 to about half way Press push button P2 once for a few seconds until DL1 lights and release After a few seconds the logic control will make some tests and then it will self learn the working time by closing the gate The board will automatically exit this mode when complete and led DL1 ...

Page 11: ...naller of potential danger for the gate s motion Motor 1 Outputs for the opening closure control of the motor which drives the first gate wing during the closing phase Motor 2 Outputs for the opening closure control of the motor which drives the gate wing delayed during the closing phase This wing can be connected with an electric lock Electric lock Impulse control for the electric lock release Th...

Page 12: ... Closing limit switch led yellow It signals the closing limit switch state for Motor 1 The led goes off when the closing limit switch is operated DL10 Opening limit switch led yellow It signals the opening limit switch state for Motor 2 The led goes off when the opening limit switch is operated DL11 Closing limit switch led yellow It signals the closing limit switch state for Motor 2 The led goes ...

Page 13: ...seconds and reopen If a command is made during the pause part of the cycle the pause time will reset and gate closing will commence later IMPORTANT If using a time clock to control the gate then apartment mode must be selected Single Wing Mode Dip switch 3 ON In single wing mode the board drives motor 2 output only MOT2 Kickback Extra Push Dip switch 4 ON If an electric lock is fitted it may be ne...

Page 14: ...que During the normal speed phase when the motor s current reaches the self learned value the gate stops both wings in opening and then it reverses its motion for approx 2 sec while during the closure phase the gate stops and reverses its motion after approx 1 5 sec After the electric power is supplied to the electronic card at installation or after one absence of power supply when the Start push ...

Page 15: ...e closes automatically The operating cycle is complete only when the closing motion has ended If a start command is supplied before the end of travel is reached the gate stops A new start command will cause the gate to reverse its motion If a start command is supplied during the pause period the operating cycle is interrupted and the gate does not close automatically A further start command will d...

Page 16: ...time is reset and the automatic closure is therefore delayed Photostop If an obstacle covers the photo cell during the gate s motion opening or closure or during the period preceding the operating cycle s start then the gate is temporarily stopped until the obstacle is removed When the obstacle is removed and the photocell is freed an opening cycle will start This does not apply when a start comma...

Page 17: ...he power devices 5 J3 8 pole removable terminal board for the connection of the limit switches and or Encoder 6 FS1 FS2 nr 2 Faston terminals for the connection of a Backup battery 7 FS3 FS4 nr 2 Faston terminals for connection of the power supply transformer Terminal board J2 Terminal1 Common terminal for all electric contacts of commands Terminal2 Pedestrian start push button s normally open ele...

Page 18: ...ut as Encoder signal TTL OPEN COLLECTOR FS1 Faston Backup battery s positive pole connection FS2 Faston Backup battery s negative pole connection FS3 Faston 12 15 20 Vac power supply from the electric transformer FS4 Faston 12 15 20 Vac power supply from the electric transformer CTR50 Connection of the devices Motor 1 Terminals 5 and 6 on J1 Motor 2 Terminals 7 and 8 on J1 Blinker Terminals 3 and ...

Page 19: ...19 ...

Page 20: ...20 ...

Page 21: ...s applied EN 61000 6 3 A11 2004 EN 61000 6 1 EN 301 489 1 EN 301 489 3 EN300 220 2 EN 300 220 1 Test laboratory NEMKO SPA Outcome Positive The manufacturer declares that the above listed products comply to the norms on electromagnetic compatibility provided for by directives 89 336 EEC 92 31 EEC 93 68 EEC Date 24 08 2007 AUTOMATIC SOLUTIONS AUSTRALIA PTY LTD PO BOX 1034 CANNING VALE WESTERN AUSTRA...

Page 22: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Reviews: