17
ELECTRICAL AND MECHANICAL SPECIFICATIONS
Dimensions and weight (with plastic box)
: 186 x 283 x 112 mm – 2.3 Kg
Power supply transformer
: 230/12-15-20 Vac - 100VA
Battery-charger capacity
: 0.5 A max
Optional battery capacity
: 12/24 Vdc – 7 Ah
Blinker power supply
: 12/24 Vdc - 15W max
Relays contacts capacity
: 20 A max
Electric lock power supply
: 12/24 Vdc - 15W max
Motor power supply
: 12/24 Vdc - 100W max (total)
Radio receiver power supply (J6)
: 12 Vdc - 2W max
Accessories power supply
: 13,5Vdc or 24Vdc - 3W max
Operating temperature range
: 0 to + 60 °C (internal)
2
nd
radio channel relay contact characteristic
: 24 Vac – 0.5 A max
Motors’ work time
: programmable, 1 to 120 sec.
Pause time
: programmable, 1 to 120 sec.
2
nd
wing closing delay
: programmable, 0 to 120 sec.
Amperometric Stop
: Automatic
Caution:
The unit must be not switched on if the connected loads or the power supply exceed the limits. Failure to observe this precaution
can result in damage to persons, animals or objects for which the manufacturer cannot be held responsible.
ELECTRICAL CONNECTIONS
7 electric connectors are fitted to the card:
1)
J2
10-pole removable terminal board for the connection of the commands and safety devices
2)
J6
10-pole connector for the optional connection of a radio receiver card
3)
J5
2-pole Terminal board for the connection of the aerial cable
4)
J1
10-pole removable terminal board for the connection of the power devices
5)
J3
8-pole removable terminal board for the connection of the limit switches and/or Encoder
6)
FS1,FS2
nr. 2 Faston terminals for the connection of a Backup battery
7)
FS3,FS4
nr. 2 Faston terminals for connection of the power supply transformer
Terminal board J2
Terminal1 - Common terminal for all electric contacts of commands
Terminal2 - Pedestrian start push-button’s normally open electric contact
Terminal3 - Start push-button’s normally open electric contact
Terminal4 - Common terminal for all electric contacts of stop push-button and photo-cell
Terminal5 - Emergency push-button’s normally closed electric contact (stop)
Terminal6 - Photo-cell’s normally closed electric contact
Terminal7 - Common terminal for the electric contact of photostop
Terminal8 - Photoelectric cell’s normally closed electric contact (photostop)
Terminal9 - 2nd radio-channel’s normally open electric contact (output)
Terminal10 - 2nd radio-channel’s normally open electric contact (output)
Important: The normally closed inputs not in use must be fitted with jumpers
Connector J6
Terminal1 – Normally open electric contact connected to the start
Terminal2 – Common of the normally open electric contact connected to the start
Terminal3 – Normally open electric contact connected to the 2nd radio-channel output
Terminal4 – Normally open electric contact connected to the 2nd radio-channel output
Terminal5 - Power supply negative (common)
Terminal6 - Power supply positive
Terminal7 - Power supply positive
Terminal8 - Power supply negative (common)
Terminal9 – Aerial input (shield)
Terminal10 – Aerial input (signal)