background image

Cod.

 CVA2031

 - 

20032013

 - 

Rev.

 08

KING 24V

Seeger E25

Spina elettrica 5 20

Spina cilindrica 8x32

Molla per sblocco serie KING

Molla trazione coperchio serie KING

Anello di tenuta OR 158

Anello di tenuta OR2037

Boccola 12x16x12 Bronzo F7/R7

Cilindretto per serratura serie KING

Dado Autob. M10 Alto Inox

Rondella Piana 10X20 Inox

Rondella Piana 10X30 Inox

Rondella Piana 12X24

Vite TCEI M6x35 zinc.

Vite TC Croce 5,5x50

Vite TCEI 6X30 Inox UNI5931

Vite TE 8X30 Inox UNI5739

Vite TE 10X40 Inox UNI 5737

CTC1123

CTC1158

CTC1214

CTC1258

CTC1259

CTC1303

CTC1307

CVA1176

CVA1325

DDD10MAI

DRL10X20I

DRL10X30I

DRL12X24Z

DTB6X35

DTC55X50Z

DTE10X20I

DTE8X30I

DTM10X40I

ACG8089

BA01019

BA10052

BA10065

BA10066

BA10102

CAL1160

CAL1162

CME6082

CCA1294

CCA1319

CCA1328

CCA1351

CCA1355

CCA1370

CCM6005ZZ

CEL1425

Gruppo Fermo meccanico di chiusura 

OPZIONALE

Serie accessori per cilindro KING

Gruppo Chiocciola serie KING

Gruppo semig. sup. KING completo

Gruppo semig. sup. KING L completo

Conf. accessori connettore, pressacavo, 

cap. coprirondella, rondella cap.

Semiguscio inferiore KING 

Semiguscio inferiore KING L

Forcella Posteriore serie KING
Piatto colonna regolabile

Piatto fissaggio colonna KING L

Piatto attacco cancello KING L

Attacco cancello serie KING

Angolare attacco a colonna (2 pezzi) KING

Piastra attacco colonna KING L

Cuscinetto motore 6005ZZ

Condensatore 10µF 450V x serie 230V/50

Codice

Denominazione Particolare

CEL1426

CME1166

CME1299

CME2042

CME2041

CME8996

CME9129

CME9130

CME9785

CME9868

CMO2515C

CPL1087

CPL1157

CPL1161

CRS62042R

CTC1004

CTC1008

CTC1119

CTC1120

Condensatore 35µF 450V x serie 120V/60

Adattat. motore KING 24V

Perno per ingranaggio serie KING

Corona elicoidale sblocco sx

Corona elicoidale dx serie KING

Vite s/fine KING 12/24V

Vite madre KING L

Vite madre KING

Perno Sblocco serie KING

Perno di traino serie KING

Motore KING 24V

Ingranaggio conico

Tappo per fermo meccanico serie KING

Ingranaggio conico serie KING

Cuscinetto 6204/2RS

Chiavetta 6 6 12

Chiavetta 6 6 30

Seeger E17

Seeger E20

Codice

Denominazione Particolare

Codice

Denominazione Particolare

Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been 
completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia

  25014 CASTENEDOLO (BS) - ITALY

Via Matteotti, 162

Tel. +39.030.2135811

Fax +39.030.21358279

www.ribind.it - ribind@ribind.it

Summary of Contents for KING 24V

Page 1: ...00 AA14028 Peso max cancello Poids maxi portail Max gate weight Max Torgewicht Peso máx verja 400 kg 880 lbs KING 24V L 24Vdc N 1800 AA14029 500 kg 1100 lbs ITALIANO pag 05 FRANÇAIS pag 16 ENGLISH page 27 DEUTSCH pag 38 ESPAÑOL pag 49 OPERATORE IRREVERSIBILE PER CANCELLI A BATTENTE OPERATEUR IRREVERSIBLE POUR PORTAILS À BATTANT IRREVERSIBLE OPERATOR FOR LEAF GATES TORANTRIEBE FÜR FLÜGELTORE OPERAD...

Page 2: ...L DATA Max leaf length Max leaf weight Max travel Average opening time Operating speed Thrust force EEC Power supply Motor capacity Power absorbed Daily operations suggested Service Guaranteed consecutive cycles Grease Weight of electroreducer Noise Volume Operating Temperature Protection m 3 5 4 5 kg 400 500 mm 345 475 s 14 27 29 38 m s 0 0125 N 1800 24V W 118 A 5 4 n 150 90 n 200 14s Bechem RHUS...

Page 3: ... If there is an iron pillar you can weld the attachment directly If there is a cement pillar you can use the fixing plate as in Fig 5 which is fastened with 4 Fischer screws of Ø 8 mm There is also the possibility to cement the attachment welding an anchor at its base Fig 6 Naturally you have to respect predetermined fixing measures Afterwards you must weld the other actuator s attachment to the g...

Page 4: ...s must be checked That the gate is endowed with appropriate handles That these appropriate handles are placed so to avoid safety risks for the operator That the physical effort necessary to move the gate leaf should not be higher than 225 N for doors gates for private dwellings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm MAINTENANCE T...

Page 5: ...5 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min Max a A max T sec B C D E 1 1 80 1 81 2 20 2 21 2 50 2 51 3 00 3 01 3 50 3 51 4 00 110 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min Max a A max T sec B C D E ANT ANT KING 24V KING 24V KING 24V KING 24V KING 24V KING 24V L KING 2...

Page 6: ...ENNA ANTENNA BRAIDING CLOSE OPEN STOP FUSE T 2 A PHOTOCELLS STEP BY STEP COMMON COMMON 24Vdc 0 8A 15 for ACCESSORY SUPPLY 24Vdc 0 8A 15 for AUTOTEST SAFETY STRIPS BLINKER 24Vdc 20W LED R 2 2K 1 4W ELECTRIC LOCK PEDESTRIAN SAFETY STRIPS POWER SUPPLY 230Vac 50 Hz TRANSFORMER M1 M2 ...

Page 7: ...amming DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Connector dedicated to the factory programming only CRX control board DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Built in radio module model CRX or connector for radio receiver RIB 24 Vdc supply Connector for charge card of 24Vdc battery code ACG4648 Trimmer for high speed adjustment operations Trimmer for low ...

Page 8: ...gate opening M1 green DL5 gate closing M1 red DL6 automatic closing indicator red DL7 photocell contact NC red DL8 sensor contact NC red DL9 STOP button NC red DL10 radio code program green FUSES Fuse 1 T 8A MOTOR PROTECTION FUSE F1 T 2A TRANSFORMER PROTECTION FUSE on the outside of the T2 24V board C MOTOR ROTATIONAL DIRECTION CONTROL 1 Set DIP 1 to ON LED DL1 starts flashing 2 Press and hold the...

Page 9: ... PROG button for 5 seconds Memory cancellation is indicated by two flashes of green LED DL10 4 The red LED DL1 remains active and you can add new codes as shown above 5 Reset DIP 1 to OFF and DIP 2 to OFF 6 End of procedure INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING Indication only when gate is stationary 1 Set DIP 1 to ON and then DIP 2 to ON 2 The green LED DL10 flashes 6 times when ...

Page 10: ... movement in front of the photocells is deactivated N B Please check photocell operation at least every six months EDGE SAFETY STRIP COM EDGE If engaged during opening reverses the motion when closing If engaged when closing reverses the motion when opening If it remains engaged again it performs a further reversal after 2 seconds then performs an additional short reversal and then gives the senso...

Page 11: ...eceiving Frequency 433 92 MHz Impedance 52 OHM Sensitivity 2 24µV Pick up time 300ms Drop time 300ms All inputs must be used as clean contacts because the power is generated internally secure power to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage Any external circuits connected to the outputs of the control panel must be made in ...

Page 12: ...0V ac dc code ACG6099 NOVA Wi Fi PHOTOCELLS WITHOUT WIRES code ACG8037 PAIR OF COLUMS NOVA code ACG8039 TOUCH Wi Fi STRIP WITHOUT WIRES code ACG3016 SPARK Wi Fi BLINKER WITHOUT WIRES code ACG7064 LATERAL SUPPORT code ACG7042 BLOCK Wi Fi KEY SELECTOR WITHOUT WIRES code ACG6098 Discover the only wireless automation devices at www ribind it SET SOLAR AMPLIFIER Interface for 50W solar panels code AD00...

Page 13: ...fissaggio colonna KING L Piatto attacco cancello KING L Attacco cancello serie KING Angolare attacco a colonna 2 pezzi KING Piastra attacco colonna KING L Cuscinetto motore 6005ZZ Condensatore 10µF 450V x serie 230V 50 Codice Denominazione Particolare CEL1426 CME1166 CME1299 CME2042 CME2041 CME8996 CME9129 CME9130 CME9785 CME9868 CMO2515C CPL1087 CPL1157 CPL1161 CRS62042R CTC1004 CTC1008 CTC1119 C...

Page 14: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Reviews: