32
32
G
B
Power supply 230 Vac 50/60 Hz - external to
the control panel - (120V/60Hz upon request)
Common contact
Closing impulse contact (NA)
Opening impulse contact (NA)
STOP impulse contact (NC)
Radio Antenna
Gate open state and battery state output
indicator (24Vdc 3W max)
+ 24Vdc safety strip self-test power supply
Safety strip contact (NC)
Common contact
Photocells contact (NC)
Single pulse contact (NO)
Pedestrian opening contact (NA)
+ 24Vdc accessories power supply
- 24Vdc accessories power supply
Electric lock connection (MAX 15W 12V)
- 24Vdc blinker (code ACG7061) power
supply.
Pay attention to the polarity.
Connection to secondary coil of transformer
18 Vac
MOTOR 1 CONNECTION (without polarity)
MOTOR 2 CONNECTION (without polarity)
Connector dedicated to the factory
programming.
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT
WORK!
Connector dedicated to the factory
programming (only CRX control board)
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT
WORK!
Built-in radio module (model CRX), or
connector for radio receiver RIB, 24 Vdc
supply
Connector for charge card of 24Vdc battery
(code ACG4648)
Trimmer for high speed adjustment operations
Trimmer for low speed adjustment operations
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL6 LED OFF)
Programming button
Motor protection fuse
Transformer protection fuse
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
TR1
TR2
TR3
S3
FUSE 1
F1
N F
COM.
CLOSE
OPEN
STOP
AERIAL
SIGNAL
A+TEST
EDGE N.C.
COM.
PHOTO N.C.
K BUTT.
PED. BUTT.
A+
A -
LOCK
SECONDARY
TRANSFORMER
MOTOR 1
MOTOR 2
SW T2 24V
SW RADIO
RADIO
BATTERY
CHARGER
TRIMMER RUN
TRIMMER
LOW SPEED
TRIMMER TCA
PROG
T 8 A
T 2 A
J3
TR2
TR1
J2
J4
F1
FUSE 1
J5
J6
TR3
J10
J8
J9
J1
J7
S3
A -
CONTROL PANEL FEATURES
TRANSFORMER