2.1 Connections to the electronic control board
A - Booth’s ON/OFF switch.
B - On switch emergency batteries after discharge.
1 - Connection with cable cv02A to door’s internal motor.
2 - Connection with cable cv01A to door’s external motor.
3 - Connection with cable cv03B to emergency batteries.
4 - Connection with cable cv07B to the internal door unlock magnet during an emergency.
5 - Connection with cable cv07A to the external door unlock magnet during an emergency.
6 - Connection with cable cv06A to the vocal message speaker.
Connection with cable cv13A lamp.
Connection with cable cv 14A to the intercom’s call button CE.
7 - Connection with cable cv08A to the power supply.
8 - Connection with cable cv12A the metal detector’s electronic control.
9 - Connection with cable cv14A to the emergency call button CE.
10 - Connection with cable cv11A to the internal proximity.
11 - Connection with cable cv10A to the external proximity.
12 - Connection with cable cv17A to the contact for the external rubber side.
13 - Cable cv18A connection to the internal rubber side and main board power contact.
14 - Connection with encoder cable to internal encoder.
15 - Connection with encoder cable to external encoder.
16 - Cable cv19A connection to the console.
17 - Cable cv05A connection to the internal push button panel.
18 - Cable cv04A connection to the external push button panel.
19 - Connection with loading cell cable to loading cell.
20 - Input connections:
- clamps 1 and 3 ON bridge.
- clamps 11 and 12 connection with cable cv09A to the mechanical lock.
- clamps 15 and 20 on first entrance bridge.
21 - Outputs connections.
22 - Connection with cable 5806791 to the SUN system (only booth’s with SUN system).
23 - Connection with cable 5806791 to the
Automatic
Systems
Metal Detector with digital console.
24 - Led self analysis.
25 - Connection with cable cv20a to the external mobile guide.
26 - Connection with cable cv21a to the internal mobile guide.