Automatic Systems
PNG38X-A3_1-04-gb-02.doc
10/12/01
p. 29/51
8.b. Management of cell C6 in the safety group (See
Chapter 4.2.7.
)
DIP 2
Configuration
0
C6 excluded from the safety zone
1
C6 included in the safety zone
8.c. Management of cell C7 in the safety group (See
Chapter 4.2.7.
)
DIP 3
Configuration
0
C7 excluded from the safety zone
1
C7 included in the safety zone
8.d. Management of cell C13 in the safety group (See
Chapter 4.2.7.
)
DIP 4
Configuration
0
C13 excluded from the safety zone
1
C13 included in the safety zone
8.e. Management of cell C14 in the safety group (See
Chapter 4.2.9.
)
DIP 5
Configuration
0
C14 excluded from the safety zone
1
C14 included in the safety zone
8.f. Management of passage authorizations (See
Chapter 4.2.7.
)
DIP 6
Configuration
0
No passage authorization storage
1
Passage authorization storage
9. Press the L.C. B push-button (
2:11
), wait for the validation signal and release the button.
10. Set the DIP switches according to the tables below in order to configure
word 3
.
10.a. Level of activation of the variable speed controller (See
Chapter 4.2.8.)
DIP 1
Configuration
0
Opening of the obstacles on VSC activation
1
Closure of obstacles on VSC activation
10.b. Detection of
opposite direction
fraud
DIP 2
Configuration
0
Detection of
opposite direction
entrance over 3 cells
1
Detection of
opposite direction
entrance over 2 cells
10.c.
Tailgating
fraud detection before passage through doors by counting the zones
DIP 3
Configuration
0
No
tailgating
detection before passage through doors
1
Tailgating
detection before passage through doors
10.d. LC locking in the event of pre-alarm or intrusion
DIP 4
Configuration
0
No LC locking on intrusion pre-alarm
1
LC locking on intrusion pre-alarm
10.e. Activation level of the
evacuation
mode
DIP 5
Configuration
0
Evacuation
if connection 5-6 of X13 is open
1
Evacuation
if connection 5-6 of X13 is closed
10.f. Detection of
opposite direction fraud
in “Free exit” mode
DIP 6
Configuration
0
Reinforced detection “
opposite direction”
in “Free exit” mode
1
Reduced detection “
opposite direction”
in “Free exit” mode
A3