Automatic Systems
PNG38X-A3_1-04-gb-02.doc
10/12/01
p. 30/51
11. Press the L.C. A and L.C.B push-button (
2:11
), wait for the validation signal and release the button. At
this moment, the buzzer may sound (e.g., in operation mode, locked).
12. Switch off the PNG main power supply.
13. Configuration for
operation of the PNG
.
13.1. If no external desk is installed, set the DIP switches according to the tables below.
13.1.a. Absence of desk
DIP 1
Configuration
0
External desk activated
1
External desk deactivated
13.1.b. Configuration direction A
DIP 2
DIP 3
Configuration
0
0
Controlled direction A
0
1
Locked direction A
1
0
Free direction A
13.1.c. Configuration direction B
DIP 4
DIP 5
Configuration
0
0
Controlled direction B
0
1
Locked direction B
1
0
Free direction B
13.1.d. Position of doors at rest
DIP 6
Configuration
0
Doors closed at rest (NF)
1
Doors open at rest (NO)
13.2.
If an external desk is installed, set all the DIP switches on OFF.
14. Reconnect the connectors X15.Low, X13.High and X13.Low.
15. Switch on the variable speed controller power supply.
16. Switch on the PNG main power supply.
From this moment on, the PNG is operational.