Automatic Systems
PNG38X-A3_1-04-gb-02.doc
10/12/01
p. 32/51
Variables:
Only the internal variables included below may be modified with the FTX117 console.
Variable
Name
Description
%M3
Lc_mem_lc
Counting the number of passage authorizations:
0: no counting
1: counting
%M9
Detect_p_t
Tailgating
fraud detection before passage through doors (DIP3 of word3):
0 : No
tailgating
detection before passage through doors
1 :
Tailgating
detection before passage through doors
%M34
Sel_pass
Type of passage contact :
0: Passage contact when the person has left the entry zone
1: Passage contact when the person has completely left the PNG
%M36
Mode_sens_contraire
Detection of
opposite direction
fraud (DIP2 of word3):
0 : Detection of
opposite direction
entrance over 3 cells
1 : Detection of
opposite direction
entrance over 2 cells
%M46
Ext_cel_a
Cell extension – direction A:
0: absent (PNG380)
1: present (PNG381-PNG382)
%M47
Ext_cel_b
Cell extension –direction B:
0: absent (PNG380-PNG381)
1: present (PNG382)
%M85
Mode_sortie_libre
Type of detection of
opposite direction fraud
in “Free exit” mode (DIP6 of word3):
0 : Reinforced detection
1 : Reduced detection
%M113
Act_evacuation
Activation level of the
evacuation
mode (DIP5 of word3):
0 :
Evacuation
if connection 5-6 of X13 is open
1 :
Evacuation
if connection 5-6 of X13 is closed
%MW0
Phase_png
Program stage.
%MW1
Cfg_pic_a
Configuration of pictograms in direction A:
0: limited management
1: extended management
%MW2
Nb_lc_a
Number of passage authorisations in direction A
%MW3
Nb_lc_b
Number of passage authorisations in direction B
%MW4
Cfg_safe
Configuration of safety system:
Bit 1
0:
C6 excluded from the group
1:
C6 included in the group
Bit 2
0:
C7 excluded from the group
1:
C7 included in the group
Bit 3
0:
C13 excluded from the group
1:
C13 included in the group
Bit 4
0:
C14 excluded from the group
1:
C14 included in the group
%MW8
Cfg_pic_b
Configuration of pictograms in direction B:
0: limited management
1: extended management
%MW12
Cel_state
State of the cells:
X15 indicates the state of the cell C1; X14 of C2; X13 of C3… X1 of CS; X0: 0
%MW21
Min_cel_zone_a
Detection of the number of zones: number of cells per zone in direction A
Default value 2.
%MW22
Min_cel_zone_b
Detection of the number of zones: number of cells per zone in direction B
default value: 2.
%MW29
Nb_cel_pass
Number of free cells for detection of passage through doors.
%MW30
Max_cel_zone
Maximum number of cells in an entrance zone before starting a zone fraud.
A3
A3
A3
A3
A3
A3
A3