Automatic Systems
PNG38X-A3_1-04-gb-02.doc
10/12/01
p. 34/51
Follow the instructions below for each time-out (from
%TM0
to
%TM12
) and monostable (
%MN0
and
%MN1
).
1.
Press the
%TM
or
%MN
key followed by the corresponding number and
ENTER
.
2.
Place the cursor on
%TMx.P
or
%MNx.P
with the vertical arrows.
3.
Introduce the new value.
4.
Press
ENTER
.
Example:
%TM0
–Buzzer alarm duration
1.
Press the
%TM
key followed by
0
and
ENTER
.
2.
Place the cursor on
%TM0.P
with the vertical arrows.
3.
Introduce the new value.
3. Press
ENTER
.
4.6. Visualization and description of entries on the PLC
FTX117 or
programme
reference
PLC LED
Attribution
I3.0
0 Cell 1
I3.1
1 Cell 2
I3.2
2 Cell 3
I3.3
3 Cell 4
I3.4
4 Cell 5
I3.5
5 Cell 6
I3.6
6 Cell 7
I3.7
7 Cell 8
I3.8
8 Cell 9
I3.9
9 Cell 10
I3.10
10 Cell 11
I3.11
11 Cell 12
I3.12
12 Cell 13
I3.13
13 Cell 14
I3.14
14 Safety cell CS
I3.15
15 VSC default
I3.16
16.0 DIP – Key
I3.17
16.1 DIP direction A – Input 1
I3.18
16.2 DIP direction A – Input 2
I3.19
16.3 DIP direction B – Input 1
I3.20
16.4 DIP direction B – Input 2
I3.21
16.5 DIP – Obstacle mode NO/NF
I3.22
16.6 Door 1 opening limit switch
I3.23
16.7 Door 1 closing limit switch
I3.24
16.8 Door 2 opening limit switch
I3.25
16.9 Door 2 closing limit switch
I3.26
16.10 Card reader – Passage authorization – Direction A
I3.27
16.11 Reader A – Badge denied
I3.28
16.12 Evacuation
I3.29
16.13 Card reader – Passage authorization– Direction B
I3.30
16.14 Reader B – Badge denied
I3.31
16.15 Safety extension
Note
: In order to display the inputs from I16.0 to I16.15 thanks to the PLC LEDs, press the « DIAG » button
for less than one second
until the digit
16
appears.