The informat ion conta ined in th is docu ment is the property of Automatic Syst ems and is conf ident ial . The recip ient shall refr ain from us ing it for any purpose
other than the use of the produ cts or t he e xecut ion of the projec t to wh ich it refers and from commun icat ing it to th ird parties w ithout wr itten pr ior agree m ent
of Automat ic Systems.
RSB76E-MT-EN
p. 16/33
4.4. VSC Parameterization (Télémécanique ATV12 )
WARNING:
it is highly advised to call upon a specialized technician for all the modifications of the
parameters.
1. Recover the Default settings:
Conf
FCS
InI
Press
ENT
key.
The Default settings are recovered as soon as
CONF
LED does not
blink.
2. Configure ATV12 for RSB 76E
:
Conf
set
default
ACC
0,1
3
DEC
0,1
3
HSP
50
50
AIIt
10 V
5V
FULL
FLt
tHt
FULL
ItH
4,6
3,5
FLt
tHt
nTn
YES
nO
FULL
drC
FrS
50
50
FULL
drC
Ufr
100
100
FULL
drC
nCr
3,8
3,5
FULL
drC
SLP
4
100
FULL
drC
SFr
16
4
FULL
drC
nPr
0,75
0,75
FULL
Fun
Stt
FULL
Stt
r MP
rMP
Fun
rrS
L2H
nO
3. Save the parameters
Conf
SCS
StrI
Press «
ENT
» key (2 seconds).
The settings are saved as soon as