15.
Ground Cable Connections
The following ground cables linking all the metal panels should be connected properly (each ground
connection on the frame is installed with a metal wire support):
1. From the frame to the central panels.
2. From the extension frame to the extension panels.
Each removable panel is grounded and attached to the frame with a metal wire held in place with a
thumbscrew.
A good quality ground cable is essential for the lane to function properly.
The ground cable should be connected directly to the main ground cable to avoid
interference and ensure proper functioning.
When mounting the removable panel back onto the frame, make sure the panel is
firmly attached to its ground cable and metal wire.