Automatic Systems
TR490-NInstall-EN
p
11/16
3.6. Check-list
Before commissioning the tripod turnstile, proceed with the various mechanical tests as
described in the Field manual
paragraph [2.1. First service at 50,000 cycles]
, then the electrical
ones (proper operation of the optional readers, pictograms, etc.). In case of a mechanical
problem, please refer to the corresponding paragraph.
Check if all wires are firmly connected to their respective terminal blocks.
Check if the tripod arms can be pushed freely if the equipment is powered off, in case a
mechanism type 3 or type 5 is installed (anti-panic device).
Check if all screws and nuts have been tightened firmly.
Inspect the inside of the turnstile to ensure no tools remain, to cause equipment failures.
Remove any foreign body from the inside of the gate (packing, debris, etc.), and clean it.
Replace and lock the hood (
4:1
).
--
The tripod turnstile is now operational. Although all adjustments have been carried out in our
factory, a final adjustment may be required, following transportation and installation of the equipment.
In this case, refer to the Field manual.
3.7. Temporary
dismantling
If the equipment has to be temporarily dismantled, e.g. if you need to change its location, follow
the procedure below.
3.7.1.
Disconnecting the equipment
--
Unlock and remove the hood (
4:1
).
--
Make sure that the power supply cables are not live.
--
Put off the main switch (
2:1
) on the electrical control logic.
--
Disconnect the power supply wires (
2:4
) from the main switch (
2:1
) as well as the earth
cable (
2:5
).
--
Disconnect any other cabling (control wires, etc.).
3.7.2.
Dismounting the tripod arms (if required)
--
Remove the flat-end screw (
5:4
) and the conic-end screw (
5:3
) from the arms (
5:2
).
--
With the help of a strap tube-wrench, turn the arms counter-clockwise to unscrew them.