background image

 

 

Automatic Systems

    

 

TR490-NInstall-EN 

 

 

 

p

8/16

 

3.2. 

Preliminary work on site 

 

This is basically the following: 

 

  Check the positioning and location of the equipment according to the site's general lay-out. 

 

  Drill holes in the ground as in Fig. 3 (page 6/11). Make sure to drill holes with the diameter 

adapted to the expansion bolts that will be used (recommended type: model B15/30, ref. 
-/3413/000).. 

 

  Make sure that cables come out at a distance of 50 mm of the fixing holes. 

 

  Prepare power supply wiring (230V single-phase + earth, 3Gx2.5) and control cabling (not 

supplied). All cables must have a 2 meter tail. 

Note: 

If you add any flammable elements (see EN60950, paragraph 4.4.5. standard) into the 
end sections of the turnstile, make sure that the floor is fireproof.

 

3.3. 

Installing the tripod turnstile 

 

Position the turnstile on site precisely. 

 

 

Tighten the expansible bolts in order to fix the turnstile on the ground. Make sure that cables are 
not trapped. 

 

 

When the turnstiles are fitted in rows of more than 1 unit, attention should be given to the linear, 
vertical and horizontal alignment.  Packing shims can be used. 

Summary of Contents for TR490

Page 1: ...od Turnstile INSTALLATION MANUAL Rev 05 Automatic Systems s a Head office factory Avenue Mercator 5 1300 Wavre Belgium Tél 32 10 23 02 11 Fax 32 10 23 02 02 Automatic Systems reserves the right to change the characteristics of its products without notice ...

Page 2: ... 4 2 1 General view p 4 2 2 Switching off the equipment p 5 2 3 General conditions of use p 5 2 4 In case of power failure p 5 2 5 Overall dimensions and installation plan p 6 3 INSTALLATION p 7 3 1 First step p 7 3 2 Preliminary work on site p 8 3 3 Installing the tripod turnstile p 8 3 4 Mounting the tripod arms p 9 3 5 Electrical connections and initial power up p 10 3 6 Check list p 11 3 7 Tem...

Page 3: ...tate to contact us with your remarks or questions WARNING YOUR TR490 TRIPOD TURNSTILE COMPRISES A MECHANISM AND VARIOUS ELECTRICAL COMPONENTS ANY NEGLIGENCE DURING AN INTERVENTION IN THE MACHINE MAY SERIOUSLY ENDANGER YOUR SAFETY AS SOON AS YOU OPEN THE HOUSING PUT OFF THE MAIN SWITCH 2 1 ON THE ELECTRICAL CONTROL LOGIC 2 2 LOCATED UNDER THE HOOD BE CAREFUL IN HANDLING ANY INTERNAL ELEMENT WHICH M...

Page 4: ...gram option 1 5 Card reader option 1 8 Electrical control logic 1 9 Floor fixing 1 5 1 8 1 10 1 4 1 3 Hood 1 10 Steel housing 1 4 1 11 Commercial identification plate Green arrow PASSAGE IN SERVICE Approach pictogram option Red cross PASSAGE OUT OF SERVICE 1 6 1 4 1 9 1 9 1 11 1 12 Lock 1 12 Note Conventionally and as a general rule the user will be considered in direction A when the turnstile is ...

Page 5: ...off the main switch 2 1 near the electrical control logic 2 2 located under the hood 2 3 General conditions of use Your TR490 tripod turnstile has been designed to operate in any climatic environment from 10 C to 50 C with up to 90 of relative humidity 2 4 In case of power failure Depending on which control mode the tripod is set up for the TR490 tripod turnstile can release the mechanism in eithe...

Page 6: ...y 230V single phase earth 3G x 2 5 Control wiring according to specifications 50 1000 950 760 800 26 5 26 5 1000 20 60 60 265 480 265 500 265 620 145 145 620 145 20 265 480 265 500 265 A A A B B B 145 EXPANSION BOLT B15 30 3413 000 recommended model A B 15 min 100 800 920 60 60 1220 50 840 265 190 190 Power supply and command cable inlet area ...

Page 7: ... material to the installation site with the assistance of a fork lift or manual hand truck and remove the packing material Unlock 4 4 and open the hood 4 3 Keys are supplied as accessories in a separate bag Raise and remove the front columns 4 1 et 4 2 Check the state of the material Though it has been carefully packed damage may have occurred during transport Any transportation damage should be r...

Page 8: ... fixing holes Prepare power supply wiring 230V single phase earth 3Gx2 5 and control cabling not supplied All cables must have a 2 meter tail Note If you add any flammable elements see EN60950 paragraph 4 4 5 standard into the end sections of the turnstile make sure that the floor is fireproof 3 3 Installing the tripod turnstile Position the turnstile on site precisely Tighten the expansible bolts...

Page 9: ...er s information and or a Health Safety Risk Assessment and apply some Loctite 243 blue or an equivalent industrial bonding adhesive on the thread Screw the arms into the central hub turn them clockwise and tighten them firmly with the help of a strap tube wrench For each of the arms fix the conic end screw 5 3 and tighten it firmly The screws are supplied as accessories in a separate bag Apply a ...

Page 10: ...3 Make sure the equipment is correctly earth bonded housing associated metalwork Proceed with all other electrical connections depending on the equipment specifications control wiring etc Route all cables via the cable entry holes and secure in the cable fastenings provided ensuring that they are held clear of the turnstile mechanism s moving parts After the power supply from the remote isolator h...

Page 11: ...nside of the gate packing debris etc and clean it Replace and lock the hood 4 1 The tripod turnstile is now operational Although all adjustments have been carried out in our factory a final adjustment may be required following transportation and installation of the equipment In this case refer to the Field manual 3 7 Temporary dismantling If the equipment has to be temporarily dismantled e g if yo...

Page 12: ...ile 3 8 Scrapping the equipment When the equipment is withdrawn from use proceed with the dismantling procedure as described in paragraph 3 7 Temporary dismantling Ensure that the various components of the equipment metals electrical components plastics etc are handled recycled or disposed of in the appropriate method to comply with regulations and codes of practice in the country where the unit i...

Page 13: ... Automatic Systems TR490 NInstall EN p13 16 4 Electric diagrams For information only The reference diagrams are inside the equipment ...

Page 14: ... Automatic Systems TR490 NInstall EN p14 16 ...

Page 15: ... Automatic Systems TR490 NInstall EN p15 16 ...

Page 16: ... Automatic Systems TR490 NInstall EN p16 16 5 EC certificate ...

Reviews: