p. 34
/46
TLxx-MT-EN-04
8. MAINTENANCE
8.1. FIRST CHECK AFTER 50,000 PASSAGES
This is an initial routine check, a simplified version of the routine maintenance:
Ground stability and cleanliness
Check the stability of the equipment and the external
cleanliness of the equipment. Use cleaning agents if
necessary (non-chlorinated)
Access to the TriLane mechanism
Remove the cover as described in paragraph "7.2.1. Removing
the cover", page 23 and the TL1 front panel.
Check for any anomalies in the moving parts of the
mechanism during the rotation of the arms
As a reminder, rotation of the arms is always possible in the
free mode (no locking). In the controlled mode, unlocking is
easily achieved by pressing the Up and Down buttons on the
HMI.
Make sure there is no abnormal noise during the rotation of
the turret.
Check for any play in the mechanism's moving components.
Check that the turret lock is working properly after rotation.
Motorisation option
If the motorisation option is present, make a few passages in
each direction to ensure that the motor is working correctly.
Remote control and reader presence.
If readers or remote controls are present, check their proper
operation.
Fixation of the arms
Check that there is no play in the fixation of the arms and the
turret.
If the dropping arm option is present, check their correct
operation in the event of a power failure. If the motor option
has also been selected, check the automatic reset when
power is turned on.
8.2. ROUTINE MAINTENANCE
Check the following every 500,000 passages and at least every 6 months:
Ground stability and cleanliness
Check the stability of the bodywork and the external cleanliness
of the equipment. Use cleaning agents if necessary (non-
chlorinated)
Access to the TriLane mechanism
Remove the cover as described in paragraph "7.2.1. Removing
the cover", page 23 and the TL1 front panel.
Check for any anomalies in the moving parts of the
mechanism during the rotation of the arms
As a reminder, rotation of the arms is always possible in the
free mode (no locking). In the controlled mode, unlocking is
easily achieved by pressing the Up and Down buttons on the
HMI.
Make sure there is no abnormal noise during the rotation of
the turret.
Check for any play in the mechanism's moving components.
Check that the shock absorber is working properly (option)
Check that the turret lock is working properly after rotation.