6.4. GENERAL DIMENSIONS AND INSTALLATION PLAN
With the TL2 housing, the power and data cables can be insert inside the housing through the right or left end box. But we
recommend a connection through the left (B) side considering that the main circuit breaker is located to the left.
min. 100*
A
A
A
B
B
B
Ø60
Ø15*
160
37.5
37.5
235
550
235
235
40
1300
754
880
210
210
550
80
Power supply and connection wiring inlet, can be through right or left end box
EXPANSIBLE ANCHOR B15/30
-/3413/000
(Suggested reference (M10))
Ø 60 mm PVC SHEATH.
Concrete
Wiring to provide for:
230 V single phase power ground, in 3G2.5 ²
IP CABLE (Ethernet) STP CAT.5
* Dimensions according to standard Automatic Systems anchoring.
Fig. 9- TL2 general dimensions and installation drawing (
plan CH9594)
340
Oblong hole 12 x 15 mm
Oblong hole
46 x 106 mm
for connecting
cables
Expansible anchor
M10
to provide
Fig. 10 Fixing points TL1 version