5.4.  SITE PREPARATION WORK

This is basically the following:
•  Study the set-up and positioning of the equipment according to the general layout of the site.
•  Drill the holes in the floor according to the specifications of the Fig. 6, page 6.
•  Be sure to drill the holes with a diameter suitable for the expandable dowels that you are going to use 

(recommended 

type: model B15/30, ref. -/3413/000)

.

•  Check the correct location of the cable passage in the middle between the mounting holes (Fig. 6, page 6).
•  Prepare the passage for the electrical control cables of the Central Control Station (not supplied) and the main 

supply cables 

(230V single-phase + earth, i.e. 3G x 2.5)

.  Provide 1.5 metres extra.

If you add any device to the front or rear end boxes of the turnstile that could ignite 

(see EN60950 standard, paragraph 

4.4.5)

, ensure that the installation surface is non-flammable.

5.5.  INSTALLING THE TURNSTILE

•  Position the turnstile precisely.
•  Ensure that the turnstile remains firmly fixed to the ground by tightening the expandable dowels. Ensure that the 

cables can pass through.

•  Make sure that all the housings of the battery are perfectly aligned and horizontal. If needed, add shims between 

the housings and the floor to ensure that they are perfectly level.

5.6.  INSTALLING THE STAINLESS STEEL ARM (VERSION WITH FIXED ARMS)

5.1

5.8

5.4

5.2

5.3

5.6

5.7

Fig. 7 - Installing the stainless steel arm

•  Put the arm (5.7) in place and push it into the housing until it stops.
•  Align the threaded hole in the arm with the hole in the turret.
•  Install the fan washer (5:1).
•  Apply one drop of Loctite* 243 

(blue)

 to the screw thread (5:8), and tighten.

•  With the dropping arm option, the 3 arms are installed from factory. 

The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose 
other than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic 
Systems. The document is subject to change without notice

.

Summary of Contents for TriLane TL1

Page 1: ...TriLane TL1 www automatic systems com TRIPOD TURNSTILE TL1 Quick Start Guide QSG Installation Instructions and Getting Started Translated from the original French version Rev 02 ...

Page 2: ...ns on the equipment must be carried out by qualified personnel Any work on this product that is unauthorized or carried out by an unqualified technician will automatically void the manufacturer s warranty о о Access to the mechanism must be reserved for staff who are aware of the electrical and mechanical risks incurred in case of negligent handling о о For any operation that does not require the ...

Page 3: ...ation label showing the equipment type the production date the voltage the weight and the serial number and the reference code 4 GENERAL 4 1 GENERAL CONDITIONS OF USE Your TriLane tripod turnstile has been designed to operate in any kind of climatic environment from 10 C to 50 C with up to 90 of relative humidity 4 2 PACKAGING In most cases your turnstile will be delivered in a cardboard box attac...

Page 4: ...n B when the tripod is on his left side 4 5 LOCATION OF THE ELECTRICAL COMPONENTS 4 19 4 17 4 18 4 16 4 15 Ref Designation 04 15 Support for electronic devices 04 16 DIN rail 04 17 Power supply 24 VDC 4 A 04 18 Main switch If you open the casing turn off the equipment by switching off the main switch 04 19 Earth terminal Fig 2 Electrical PC board left The information contained in this document is ...

Page 5: ...rnstile has been specially packaged for transport Bring the material to the installation site with the help of a forklift truck and remove the packing material Remove the top cover two screws M6 see attached picture to access the mechanism the motor control board optional and the functional pictograms Open the front panel with the two keys to get access to the main control board the main switch an...

Page 6: ...NO AARDE IN 3G2 5 KABEL IP Ethernet STP CAT 5 POWER SUPPLY SINGLE PHASE 230V MONO T IN 3G2 5 IP CABLE Ethernet STP CAT 5 SPANNUNGSVERSORGUNG 230V EINPHASIG ERDE 3X2 5 KABEL NETZWERK Ethernet STP CAT 5 ZONE D ARRIVEE DES CABLES D ALIMENTATION ET DE COMMANDE AAMKOMST VOEDINGSKABELS EN VERBINDINGSKABELS POWER SUPPLY AND CONNECTION WIRING INLET BEREICH FÜR KABELZUFÜHRUNG FÜR SPANNUNGS UND STEUERLEITUN...

Page 7: ...urnstile remains firmly fixed to the ground by tightening the expandable dowels Ensure that the cables can pass through Make sure that all the housings of the battery are perfectly aligned and horizontal If needed add shims between the housings and the floor to ensure that they are perfectly level 5 6 INSTALLING THE STAINLESS STEEL ARM VERSION WITH FIXED ARMS 5 1 5 8 5 4 5 2 5 3 5 6 5 7 Fig 7 Inst...

Page 8: ...all and fix the top cover Check the functionalities Pictograms locking mechanism fraud detection performing a few passages in both directions The tripod turnstile is now operational All the settings have been made in the factory at the time of the working tests Some additional adjustment could nevertheless be necessary as a result of transport or handling during assembly In such cases refer to the...

Page 9: ...CE OF SURFACES To retain the surface appearance and avoid any oxidation deposits or marks it is strongly recommended to regularly treat the stainless steel surface with a product specially designed for this purpose Automatic Systems can provide an approved product under reference 6031 000 Automatic Systems reserves the right to deny warranty coverage in the case of an apparent lack of maintenance ...

Page 10: ...ctro magnet from heating up The turret will not re lock during rotation Check the operation of the angular sensor and the connecting cable CN17 on the AS1635 circuit board In the case of an angular sensor problem an error appears on the HMI display The TriLane does not operate and the LED LD1 on the AS1635 circuit board is off The AS1365 control circuit board is not powered with 24 VDC Check the 2...

Page 11: ...atic systems com Tel 32 10 23 02 27 Fax 32 10 86 22 90 Belgium Wallonia Brussels Tel 32 70 22 44 66 Fax 32 10 86 22 90 Email helpdesk be automatic systems com Belgium Flanders Tel 32 70 22 44 66 Fax 32 3 88 700 76 Email dnv be automatic systems com Canada Tel 1 450 659 0737 Fax 1 450 659 0966 Email helpdesk nam automatic systems com China Tel 86 512 5383 0561 Email helpdesk cn automatic systems co...

Reviews:

Related manuals for TriLane TL1