Owner Installation Instructions
GDO-10V1 Toro
®
31
cause the door to stop. The next trigger will move
the door in the opposite direction to that last
travelled.
When GPI Input Is Confi gured As Ped :
The activation of GPI input or by transmitter button
with PED function assigned will opens the door
partially to allow pedestrian access but prevent
vehicle access. The position the door is driven to
is automatically set to halfway during setting of
the travel limits, but can be adjusted to suit.
When GPI Input Is Confi gured As Day
Light Saving
The GPI input can be used to switch between STD
time and DST (daylight savings time). The time
selected is the amount of time added to STD time
when DST is Selected.
Options are OFF, 30, 60, 90 or 120 minutes. The GPI
input needs to be constantly active to show day light
saving time.
7.5 PED Input Function
If GPI Or Fire Input Is Selected As Ped Then These
inputs can be confi gured to a SWIPE type input for
pedestrian access. This provides full functionality
with the PE Beams Triggered Pedestrian auto-close
function.
7.6 Open Input Polarity
The OPN input is normally confi gured for N/O operation.
This parameter allows its operation to be changed to N/C.
7.7 Open Input As 2nd PE Beams Input
By selecting this parameter will allow the OPN input to be
used as second PE beams input. When the OPN input is
active, the door is prevented from being closed. If the
OPN input is triggered while the door is closing, the
controller will stop the motor and then open the door.
The OPN input has no effect while the door is opening.
The 2nd PE Beams (OPN) input must be active when
the PE Beams input is activated in order for PE Beams
triggered auto-close to be activated .
7.8 STOP Input Polarity
The STP input is normally confi gured for N/O operation.
This parameter allows its operation to be changed to N/C.
7.9 FIRE Input Polarity
The FIRE input is normally confi gured for N/O operation.
This parameter allows its operation to be changed to N/C.
7.10 FIRE Input Confi guration
Fire input can be confi guration as OPN ,CLS (available
only if PE Beams are installed )or PED function.
Activated by FIRE input terminal with N/O or N/C (if
selected) switch.
When Fire Input Is Confi gured As CLS :
Activating the fi re input will cause the door to close
only if PE Beams are installed. Holding the input active
will prevent from opening.
Control Board Adjustments
When Fire Input Is Confi gured As PED:
The activation of fi re input will opens the door partially to allow
pedestrian access but prevent vehicle access. The position the
door is driven to is automatically set to halfway during setting of
the travel limits, but can be adjusted to suit.
When Fire Input Is Confi gured As OPN :
Activating the fi re input will cause the door to open. Holding the
input will prevent from closing.
7.11 Remote Code
The controller supports the Remote Code Set feature. This parameter
can be used to disable the feature for security or transmitter
management reasons.
7.12 Activity Reports
This parameter enables activity report outputs. Contact Automatic
Technology for more details.
7.13 Activity Report ID
This parameter sets the ID of the controller that is sent with the
activity report. Contact Automatic Technology for more details.
7.14 Vacation Mode
Vacation mode can be turned on or off using
this parameter.
7.15 Standdby Battery Enable/Disable
The controller can be instructed to turn off the battery Back Up facilities
so that the control board can be shut down without having to disconnect
the battery Back Up system.
7.16 Password Protection
The password feature enables all parameters and confi guration
settings to be protected unless a password is entered. When this
feature is turned on the user is requested to enter the desired
password to be used. The password protection feature has a time-
out that expires after 60 seconds of inactivity. Alternately the user
may log out manually by pressing exit when the main screen is
displayed.
7.17 Transmitter Grouping
The transmitter store number display format can be changed to
show a grouped format. When grouping is selected, instead of
displaying.The store location as a number between 1 and 511, it is
displayed
As ##$ where ## is the group number and $ is a character
a,b,c,d,e,f,g or h which indicates the group member.
7.18 Fault, Auto Reset
When selected the controller will reset any fault automatically.
7.19 Led Low Power Mode
When led low power mode selected the controller will turn the led
power off to save the power.
7.20 console OSC Buttons
console can be locked out by selecting console osc buttons of
f