36
GDO-10V1 Toro
®
Owner Installation Instructions
Service Counter
(Cycles) 60000
1: Open Cycles
(Cycles) 500
59
fi g
58
fi g
Menu 9.5 Service Counter
The opener provides a periodic service counter which
can be set to expire after a number of drive cycles.
When expired, the opener will beep three times at
the beginning of each drive cycle and a message will
be displayed on the MAIN SCREEN
(Fig. 58).
This
tool displays the current value of the service counter
and allows the user to set its value using the normal
parameter editing techniques (See PARAMETER
VIEWING AND EDITING). If the service counter is
not to be used it can be set to the maximum number
(60,000).
Menu 9.6 Counters
The opener keeps a count of number of times a
particular event occurs. The list of event counters
kept is shown below. When this tool is selected the
fi rst event counter is shown
(Fig. 59).
Press NEXT or
PREV to step through the list. The example shows the
OPEN CYCLE event counter with a value of 500. When
fi nished viewing press STOP.
1: Open Cycles 2: Close Cycles
3: Ped Cycles 4: Warranty Cycles
5: Open Obstructions 6: Close Obstructions
7: Open O/Ls 8: Close O/Ls
9: Setup Limits 10: Drive Faults
11: Volt Faults 12: Amp Faults
13: Supply High Faults 14: Supply Low Faults
15: Amp Trip Faults 16: Position Sensor faults
17: Drive Memory Faults 18: Position Wrap Faults
19: Direction Faults
Memory Tools
The Memory Tools accessed from within Menu 10
(Fig.
60)
are used to clear the transmitters codes from the
openers memory and clear the controller’s memory.
Once selected the PREV or NEXT buttons can be used
to view the Memory Tool options. To Execute the
displayed option simply press SET.
Menu 10.1 Clr Control
This option will clear the door control memory and
reload the factory set defaults for parameters such as
the lock time, light time, auto-close times etc. It will
also clear the travel limits.
Menu 10.2 Clr Tx’ers
This option will clear the transmitter storage memory.
MENU 10
Memomry Tools
60
fi g
Diagnostic tools menu 9