background image

GDO-12 HIRO Installation Manual

11

6.5 Setting Limits

HELPFUL TIP: Alternatively set travel limits 

using a transmitter, allowing free movement 

around the garage to better assess the 

desired limit positions. See Appendix D. 

tip

Fig 6.5

6.5.1 Set the Limit Positions and adjust drive speed:

The Limit Positions can vary due to site conditions, such as 

uneven ground. When setting the Close limit, ensure the 

position is when the door makes first contact with the ground. 

Alternatively for the Open limit the position should be at the 

height of the garage opening.

NOTE: The drive speed is set to the fastest setting by default. 

This may not be suitable for larger doors. 

a. Move the door to the half way position.

b. Engage the opener by pulling down on the manual release 

string until a click sounds. 

c. Switch power on and the BLUE LED on the BLUE CLOSE 

button will start to flash. 

WARNING! In setting the close limit 

position, do not force the door into the floor 

with excessive force, as this can interfere 

with the ease of operation of the manual 

release mechanism.

WARNING! The door will automatically close, 

open and close again after the next step. 

Ensure that nothing is in the door’s path.

NOTE: If unhappy with the speed or travel limit setting, 

restart this procedure by clearing the door limit positions as 

per below first.

6.5.2 Clearing the Door Limit Positions

Limit positions can be deleted by:

a. Switching off power to the unit.

b. Pressing and holding the RED STOP / SET button and 

switching power on to the unit will clear the settings 

memory. (the LIMIT LED will flash).

c. Follow from CLOSE limit: above to set new limit 

positions.

CLOSE limit:  

(i) Press and hold the CLOSE button to start closing the door, 

taking note of the speed the door moves. 

(ii) If the close speed is not suitable, to make a change, press 

and hold  the CLOSE button and by pressing the  

RED STOP / SET button on the opener it will cycle through 

all three speed modes as shown in table. 

Fig 6.5

(iii) Once at the desired speed, release the CLOSE button. 

(iv) To set the close limit, inch the door by making single 

presses of the CLOSE button to the desired position. We 

recommend the CLOSE limit position being the first point 

of contact of the rubber strip ( at the bottom of the door) 

with the ground.

(v) If the door overshoots, press the OPEN button  to move 

the door in the OPEN direction.

(vi) When the door is at the desired CLOSE position, press the 

STOP / SET button on the opener, the GREEN LED on the 

OPEN button  will now flash.

OPEN limit:  

(i) Press and hold the OPEN button to start opening the door, 

taking note of the speed the door moves. 

(ii) If the open speed is not suitable, to make a change, press 

and hold  the OPEN button and by pressing the  

STOP / SET button on the opener it will cycle through all 

three speed modes as shown in table.

(iii) Once at the desired speed, release the OPEN button. 

(iv) Continue inching the door to the desired position. 

(v) To set the open limit, inch the door by making single 

presses of the OPEN button to the desired position. We 

recommend the OPEN limit position being the height of 

the garage opening.

(vi) If the door overshoots, press the CLOSE button to move 

the door in the CLOSE direction.

(vii)  When the door is at the desired OPEN position, press the 

STOP / SET button The door will now automatically close 

and open to calculate the safety obstruction settings.

6.5.3 Re-profiling the Door

Re-profiling is a simplified way of re-learning the travel 

characteristic of a previously setup  Limit Switch travel 

installation. Re-profiling can be used when the travel 

characteristics of the door change due to mechanical 

adjustments etc. To initiate a re-profile:

a. Limits must be set.

b. Press the MODE button repetitively until the LIMIT LED is 

lit.

c. One of the word LEDs (LAMP etc) will highlight. Press the 

BLUE CLOSE button to move to OBST

d. Press and hold the STOP / SET button for two seconds, 

the door will open and close by itself to record profile.

Door Opener 

Speed Mode

STATUS

BEEP

Fast (Default)

On

3 Beeps

Medium 

On

2 Beeps

Slow

On

1 Beeps

HELPFUL TIP: The door can be set to a 

partial open position and programmed to a 

transmitter button. Refer to Appendix B. 

tip

Summary of Contents for HiRO GDO-12

Page 1: ...GDO 12 HiR Doc 160421_00 Released 01 04 20 High Rolling Door Opener Installation Manual ...

Page 2: ...ugthathasathird grounding pin This plug will only fit into a grounding type outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way This operator is not equipped for permanent wiring Contact a qualified electrician to install a suitable receptacle if one is not available September 2018 Automatic Technology Austr...

Page 3: ...6 7 4 Activate Remote Code Set Mode 13 7 Operation Instructions 14 7 1 How to Use Your Opener 15 7 1 1 To Operate the opener 15 7 1 2 Replacing the Battery 3V Lithium Battery CR2032 15 7 1 3 Battery Disposal 15 7 2 User Operating Controls 16 7 3 Door Status Indicators 16 8 Troubleshooting Guide 17 9 After Installation Care 18 9 1 Service Checklist 18 9 2 Battery Replacement 19 9 3 Battery Disposal...

Page 4: ...install the proper outlet Do not change the plug in any way If the power cord is damaged it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard Connect the power cord only to properly earthed mains If an extension lead must be used make sure it is a 3 core lead and approved to 7 amp capacity This unit is not user serviceable Unplug the ...

Page 5: ...or must be well balanced and able to be operated by hand as per warranty conditions and standard AS NZS 4505 2012 6 turns of the drum wheel 270kg 22m2 28m2 Minimum sideroom 35mm IP rating IP20 Receiver type Multi frequency UHF FM 433 47 433 92 434 37MHz Receiver code storage capacity 64 x 4 button Transmitters Number of code combinations Over 100 billion random codes Transmitter battery CR2032 3 V...

Page 6: ... GDO 12 POWER DRIVE UNIT 1 2 INTERNAL GEAR ADAPTER FORKS 3 3 HEX SERRATION HEAD SCREW M6 X 20 6 4 4 BUTTON TRANSMITTERS 2 5 4 BUTTON WALL TRANSMITTER 1 6 LOCKING BAR COVERS 2 GUIDE PACK VR12 7 SCREW EYE 2 8 PLASTIC WALL PLUG 6 9 X 25 1 2 REGISTRATION CARD Please retain for optional smart phone control kit 1 2 3 4 5 6 7 8 ...

Page 7: ...et for right hand side installation This opener must be installed in a dry position that is protected from the weather Moisture or corrosion damage is not covered by the Warranty 4 4 Power Supply Properly earthed 3 pin single phase power is required WARNING Using a portable power generator is not recommended The opener may appear to malfunction due to spikes surges and fluctuations in the generate...

Page 8: ... Section 6 4 3 Resetting Door Limit Positions 6 Installation Instructions IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of severe injury or death 1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS 2 Install only on a properly operating and balanced garage door An improperly balanced door has the potential to inflict severe injury Have a qualified service person make repairs to cables...

Page 9: ...be positioned as low as possible in the grove but make sure that it does not alter the curtain s normal lead in to the guide BALLOONING DOOR PINNED DOOR FREE DOOR Pin Points Screw into the low part of grove Check that the door is still balanced and smooth to operate If it is not the door may require servicing refer to door manufacturer s instructions 6 2 1 Door prop preparation a At the end opposi...

Page 10: ...ng when the beam is blocked by a car child etc When the Safety Beam Kit is installed the Auto close feature can be enabled if required To install the Safety Beam Kit refer to the Safety Beam instruction supplied with the kit 6 3 Fitting the Opener 6 4 Auto Close WARNING It is compulsory to have Safety Beams installed when using Auto Close mode Auto Close mode is a function that automatically close...

Page 11: ...desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the CLOSE limit position being the first point of contact of the rubber strip at the bottom of the door with the ground v If the door overshoots press the OPEN button to move the door in the OPEN direction vi When the door is at the desire...

Page 12: ...G THE BATTERY THERE ARE NO OTHER USER SERVICEABLE PARTS TESTED TO COMPLY WITH FCC STANDARD FOR HOME OR OFFICE USE OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION NOTE THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMIT...

Page 13: ... NOTE Only the function of the existing transmitter button can be assigned to new transmitter Please read instructions prior to proceeding there is a time out facility for security reasons 6 7 3 Selecting The Function To Be Coded a Using the existing transmitter operate the Door with the transmitter button which has the function to be coded e g Button 1 has been coded with the OSC function assigne...

Page 14: ...RAVEL RETEST THE DOOR OPENER FAILURE TO ADJUST THE OPENER PROPERLY INCREASES THE RISK OF SEVERE INJURY OR DEATH 6 FOR PRODUCTS HAVING AN EMERGENCY RELEASE WHEN POSSIBLE USE THE EMERGENCY RELEASE ONLY WHEN THE DOOR IS CLOSED USE CAUTION WHEN USING THIS RELEASE WITH THE DOOR OPEN WEAK OR BROKEN SPRINGS ARE CAPABLE OF INCREASING THE RATE OF DOOR CLOSURE AND INCREASING THE RISK OF SEVERE INJURY OR DEA...

Page 15: ...th Australian Battery Recycling Initiative please follow the next simple steps for protecting the environment Refer to the Automatic Technology website for information on where to recycle batteries in Australia DO NOT throw the batteries in municipal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in the municipal waste Check your local regulations ...

Page 16: ...hen opening Flashing On and door will stop Door obstructed when closing Flashing Beeps while door is moving Opener overloaded Alternating flashes Alternating flashes Mains power interrupted Rapid flashes HELPFUL TIP Refer to Appendix C for Additional LED Indicators tip 7 2 User Operating Controls Button Function 1 BLUE DOWN ARROW Close Button 2 RED STOP SET Stop Set Button 3 GREEN UP ARROW Open Bu...

Page 17: ...ion 7 1 1 Refer to battery status Seciton 7 1 2 Change the position Section 7 1 The door reverses for no apparent reason This may occur occasionally from environmental conditions such as areas that are windy dusty or have extreme temperature changes If Safety Beams are installed they may be partially obstructed Put the door into manual Section 5 take note of the CAUTION and contact 1300 133 944 En...

Page 18: ... mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door opens and closes to specification 5 Assessment and adjustment of safety components and accessories including safety beams Auto Lock and Safe Lock if installed 6 Assessment of the door alignment and the di...

Page 19: ...tter button Check Light Status table to determine if battery needs replacing Light Status Battery Status Solid OK Flashing Requires replacement No light Requires replacement Use a pen to push the battery down through the side opening to release battery Use finger nails to separate the transmitter casing to expose circuit board Use a non metallic object e g pen to remove the battery Some batteries ...

Page 20: ...he OPEN STOP and CLOSE LEDS will now flash and indicate the parameters value as shown in table below f Use the BLUE CLOSE or GREEN OPEN buttons to adjust the parameter value by one step up or down g Press RED STOP SET to save the new value or MODE to cancel the edit flashing will stop h To enter another parameter repeat from Step a Appendix When activated PET mode drives the door to a preset posit...

Page 21: ... auto close timer was paused due to the beam being blocked FLASHES to indicate the auto close timer is running BEAM LED On STEADY when a beam is blocked FLASHES when there is a P E Fault OBST LED On STEADY Obstruction was detected If door open then obstruction was while closing and vice versa FLASHES Stall Overload detected If door open then stall overload while closing and vice versa SPANNER LED ...

Page 22: ... the button 4 will move the door to desired limit ii While inching to CLOSE to set the close speed press and hold button 4 on the remote and by pressing the SET button 2 the opener will cycle through all three speed modes as shown in table iii Once at the desired speed release the remote button 4 iv Continue inching the door to the desired position We recommend the CLOSE limit position being the f...

Page 23: ... button f Press the transmitter button to test E 3 Transmitter Button to Operate PART Partial Mode The PART mode position see 11 Setting Partial Open Position must set prior to coding a transmitter a Press the MODE button to highlight the CODE LED if not already highlighted b Use the BLUE CLOSE or GREEN OPEN buttons to scroll through to highlight the PET LED c Press and hold the RED STOP SET butto...

Page 24: ...chnology office location Head Office 6 8 Fiveways Blvd Keysborough 3073 Phone 03 9791 2000 ata aust com au Prefixed trademarks are the property of Automatic Technology Australia Pty Ltd ABN 11 007 125 368 2020 Automatic Technology Australia Pty Ltd ...