14
Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-500 / NES-800
14. Accessories Installation
LIGHT REL
AY MODULE
POW
ER
SUPPL
Y
V+
0V
SAFETY B2
SAFETY B1
OV
OPEN
STOP
CLOSE
OSC
SWIPE
PEDESTRIAN
OV
V+
OUT2
V+
OUT1
Wiring Output1 And Output2
Outputs 1 and 2 are used to control a lock, Light or Safety Beam power. Which output is to control which function and
the way it is controlled is programmable. If using these outputs make sure that the functions are configured for correct
operation prior to setting the travel limits. OUTPUT1 or OUTPUT2 is used to activate an optional external relay module
(RO-1) which in turn is used to switch the load.
14.1 Fitting Solenoid Or Magnetic Locks
Install the lock mechanism on the gate as per the
manufacturers instructions. See
Fig. 14.1
for the
wiring diagram.
Menu 4. Lock Times
Lock output can be programmed for both hold
and pulse mode. The operation of the lock can
be programmed to activate prior to the gate and
behave differently on open cycles to that on close
cycles.
a. Press NEXT or PREV on the wall control unit to
navigate to Menu 4 Lock Times.
b. Press SET to select the sub menu.
c. Press NEXT or PREV to navigate through the
sub menu.
d. Press OPEN to increase or CLOSE to decrease
the time.
e. Press SET to save the new time.
f. Press the EXIT button two times to exit and test
the locks operation.
Pulse Lock
LOCK REL
AY MODULE
POW
ER
SUPPL
Y
V+
0V
SAFETY B2
SAFETY B1
OV
OPEN
STOP
CLOSE
OSC
SWIPE
PEDESTRIAN
OV
V+
OUT2
V+
OUT1
Fig 16.1
Fig 16.2
14.2 Fitting Courtesy Lights
An AC or DC courtesy light can be activated via an
output on the gate opener control board. Connect
the light as per the diagram.
(Fig. 14.2)
WARNING: A qualified electrician must
perform the installation where 240V
AC power is used.
Menu 5. Light Times
a. Press NEXT or PREV on the wall control unit to
navigate to Menu 5 Light/Lock Times.
b. Press SET to select the sub menu.
c. Press NEXT or PREV to navigate through the
sub menu.
d. Press OPEN to increase or CLOSE to decrease
the time.
e. Press SET to save the new time.
f. Press the EXIT button two times to exit.