Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-500 / NES-800
21
Parameter
Option
Default
Menu
Section
Menu 9 - Memory Tools
CLR CONTROL
9.1
Appendix E
CLR TRANSMITTERS (TX’ERS)
9.2
Appendix E
Menu 10 - Setup Travel
LIMIT TRAVEL
10.1
8.1
REPROFILE TRAVEL
10.2
9.5
SET PEDESTRIAN
10.3
14.1
Appendix
C - Wiring Dual NeoSlider Kit
MOTOR 2 TERMINAL 1
MOTOR 2 TERMINAL 2
MOTOR 2 CLOSE LIMIT SWITCH INPUT
MOTOR 2 OPEN LIMIT SWITCH INPUT
COMMON FOR MOTOR 1 & 2 LIMIT SWITCHES
MOTOR 1 CLOSE LIMIT SWITCH INPUT
MOTOR 1 OPEN LIMIT SWITCH INPUT
MOTOR 1 TERMINAL 1
MOTOR 1 TERMINAL 2
V PWR FOR ACCESSORIES
OV
Limits
M
ot
or
C
O
Co
m
1
2
MSI-1.00 Board
Limits
M
ot
or
C
O
Co
m
1
2
MSI-1.00 Board
ATA DCB-05V2 (150VA)
Red
Black
White
Blue
Orange
Black
White
Orange
Red
Blue
Fig C.1
This section illustrates how to wire two NeoSlider slave units into a DCB-05V3.
(Fig. C.1)
NOTE:
When setting limits, if both openers are travelling in different directions (i.e one is opening and the other is closing),
then do the following:
a. Switch over the motor wires (marked red and black in
Fig C.1
) on the incorrectly behaving openers MSI board.
b. Restart the limit set up process via the DCB-05V3 Manual.