Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-500 / NES-800
23
The controller provides several diagnostic tools from within the Diagnostics
Menu (Menu 8). This section details the function of each tool and its use.
Navigating To Diagnostics Menu
a. Press PREV to navigate to Menu 8
(Fig. E.1)
.
b. Press SET to display the menu of available functions.
c. Press PREV or NEXT to cycle through diagnostic tools.
d. Press SET to select.
Menu 8.1 Test Inputs
This tool is used to view the state of the control inputs. When selected, a
screen is displayed
(Fig. E.2
)
which indicates the state of each input. If the
name of the input is in upper case or number in the bracket, then the input
is active. Conversely if the input is in lower case, then the input is inactive.
For normal operation, all inputs should be inactive. When finished, press
EXIT. The example shows the status as OSC input is active.
Menu 8.2 Test Transmitters (Tx’ers)
This tool is used to test receiver/transmitter functionality. When selected, a
screen is displayed which prompts for a transmitter button to be pressed
(Fig. E.3)
and whether ID or serial numbers are to be displayed.
The NeoSlider™ will then beep each time a transmission is received. If the
transmitter button is stored in the NeoSlider™ memory and has a function
assigned to it, a second screen will be displayed that shows the transmitter
details along with the button pressed
(Fig. E.4
)
.
The example shows the case where transmitter number 12 is
activated by button 4. Note ID is selected for display.
Menu 8.3 Display History
The NeoSlider™ keeps a record of the last 64 events that have
taken place. The events include the type of drive cycles executed,
obstruction detection, various faults, power failures etc. When this
tool is selected, the screen displays the last event that occurred
(Fig. E.5)
.
Press NEXT or PREV to view each event. The “EVENT#” field shows
the sequence of the events, with (1) being the first and (64) being the last.
The example shows that the last event was a close cycle which succeeded in
closing the gate. When finished viewing the events, press EXIT.
Menu 8.4 Memory Usage
This tool displays the number of transmitter store locations used and the
number free
.
Fig E.1
Fig E.2
Fig E.3
Fig E.4
Fig E.5
E- Diagnostic Tools
Appendix
MENU 8
Diagnostics
PRESS
I/P: pe opn stp
cls OSC swp ped
PRESS TX’ER
<-/->
Shows ID/SN
12
ID
B B SMITH
OSC PED LGT>VAC
PRESS
Close Complete
EVENT# 64