Pre-Installation Requirements
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION
Warning: Incorrect installation can lead to severe injury.
Follow ALL installation instructions.
04
fi g
NOTE:
Planetary chain equipment must be removed from
the door prior to installation of GDO-10v2.
Door Operation
The door must be in good operating condition. The
maximum effort to move the door up or down, from
stationary, should not exceed 150 Newtons (15 kg force) at
the bottom rail.
Lift the door to about halfway. When released, the door
should stay in place supported entirely by its springs. Raise
and lower the door to check for binding or sticking.
The door may need to be serviced to meet these
requirements – refer to the door manufacturer’s servicing
instructions or contact an authorised dealer.
Unsuitable Door Types
The fi tting of an opener to doors with removable mullions or
doors incorporating a wicket door
is not recommended.
Position
The opener can be installed on either the right- or left hand
side of the door (when viewed from inside the garage). The
opener is factory set for right hand side installation.
This opener must be installed in a dry position that is
protected from the weather. Moisture or corrosion damage
is not covered by the Warranty.
Power Supply
Properly earthed 3 pin single-phase power is required.
WARNING! Using a portable power generator
is not recommended. The opener may appear
to malfunction due to spikes, surges and
fl uctuations in the generated voltage.
Sideroom For Right Hand Side Installation
The minimum sideroom required from the edge of the door
curtain is 140 mm to the inside of the door bracket when the
opener is mounted on the door bracket
(Fig. 04)
.
NOTE:
The door axle diameter must not exceed 35mm.
140
185