18
GDO-10V2 Toro
™
Owner Installation Instructions
Setting Limits: Via Transmitter
17
fi g
The GDO-10v2 has the alternate ability to set travel
limits using the transmitter, allowing free movement
around the garage to better assess the desired limit
positions. In order to use a transmitter, it must fi rst have
at least one of its buttons coded to the door controller.
The function assigned to the transmitter’s buttons is of
no concern here as the buttons are temporally assigned
to OPEN, CLOSE and SET
(Fig. 18)
.
Step 7 -
Code A Transmitter For Limit Setting
Step 7.1 - Navigating to “code transmitter”
menu
1. Press NEXT to navigate to Menu 1.
2. Press SET to enter the code set procedure
(Fig. 17)
.
Step 7.2 - Storing Transmitter Code
1. Controller will prompt to press one of the
transmitter’s button.
2. Press the transmitter button you wish to use to
operate the door opener (e.g. button 1) .
3. Press the same transmitter button again as
prompted by display.
4. Press the set button to store the transmitter.
Step 7.3 - Navigating To “Set Door Travel
Menu”
1. Press PREV to navigate to Menu 10.
2. Press SET to display MENU 10.1.
3. Press SET two times to enter the limit setting
procedure. The close blue LED will start to fl ash.
Setting Limits Via Transmitter
Press and hold Button 4 on the transmitter to close the
door.
If the door opens, release button 4 and press
the stop button once on the wall control unit to
change the direction of the motor. Then press
and hold Button 4 on the transmitter to close
the door.
If the door is closed too far, press Button 1 to
“inch” the door towards open.
When happy with the close limit position, press
Button 2 to store this in the memory. The open
green LED will starts to fl ash.
Press Button 1 to open the door.
If the door is opened too far, press Button 4 to
“inch” the door towards close
WARNING: The door will automatically close
and open once next step is performed. Ensure
that no persons or objects are in the door’s
path.
When happy with the open limit position, press Button 2
on the transmitter to store into memory.
The door will now automatically close and open to calculate
the safety obstruction settings. After this, if PE Beams are
installed, then the opener can be operated with the OPEN
or CLOSE button on the wall control unit or from the
transmitter. Otherwise, the controller will be loaded with
“Safety Close Mode”. (Page 29)
»
»
»
Button 1
(Inch Open)
Button 4
(Inch Close)
Button 2
(Set)
MENU 1
Code Transmitter
PR E S S
18
fi g