Owner Installation Instructions
GDO-10V2 Toro
™
31
Menu 6.10 FIRE Input Polarity
The FIRE input is normally confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 6.11 FIRE Input Confi guration
Fire input can be confi guration as OPN ,CLS (available only if PE Beams are installed) or PED function. Activated by FIRE
input terminal with N/O or N/C (if selected) switch.
When Fire Input Is Confi gured As CLS :
Activating the fi re input will cause the door to close only if PE Beams are installed. Holding the input active will prevent
door from opening.
When Fire Input Is Confi gured As PED:
The activation of fi re input will open the door partially to allow pedestrian access but prevent vehicle access. The
position the door is driven to is automatically set to halfway during setting of the travel limits, but can be adjusted
to suit.
When Fire Input Is Confi gured As OPN :
Activating the fi re input will cause the door to open. Holding the input will prevent the door from closing.
6.12 Remote Code
The controller supports the Remote Code Set feature. This parameter can be used to disable the feature for security or
transmitter management reasons.
6.13 Activity Reports
This parameter enables activity report outputs. Contact Automatic Technology for more details.
6.14 Activity Report ID
This parameter sets the ID of the controller that is sent with the activity report. Contact Automatic Technology for more
details.
6.15 Vacation Mode
Vacation Mode can be turned on or off using this parameter.
6.16 Standdby Battery Enable/Disable
The controller can be instructed to turn off the Battery Backup facilities so that the control board can be shut down without
having to disconnect the Battery Backup system.
6.17 Password Protection
The password feature enables all parameters and confi guration settings to be protected unless a password is entered.
When this feature is turned on, the user is requested to enter the desired password to be used. The password
protection feature has a time-out that expires after 60 seconds of inactivity. Alternatively, the user may log out manually
by pressing exit when the main screen is displayed.
6.18 Transmitter Grouping
The transmitter store number display format can be changed to show a grouped format. When grouping is selected,
instead of displaying the store location as a number between 1 and 511, it will display as ##$ where ## is the group
number and $ is a character a,b,c,d,e,f,g or h which indicates the group member.
6.19 Fault, Auto Reset
When selected, the controller will reset any fault automatically.
6.20 LED Low Power Mode
When LED low power mode is selected, the controller will turn the LED power off to save the power.
6.21 Console OSC Buttons
Console can be locked out by selecting console OSC buttons OFF.
Control Board Adjustments