background image

1

Sales 800-633-0405

www.productivity2000.com

Terminal Block sold separately, (see wiring options on page 5).

Warranty: Thirty-day money-back guarantee. Two-year limited 

replacement. (See www.productivity2000.com for details).

®

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and to 

verify that the equipment, installation, and operation are in compliance with 

the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the 

failure to follow all applicable codes and standards. We do not guarantee 

the products described in this publication are suitable for your particular 

application, nor do we assume any responsibility for your product design, 

installation, or operation.

If you have any questions concerning the installation or operation of 

this equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time 

it was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

Connector Specifications

Connector Type

24-Pin Molex Style 43025-2400

Number of Pins

24

Pin Spacing

3x3 mm (0.118 x 0.118 in)

P2-16ADL-1 Analog Input

The P2-16ADL-1 Low Resolution Current 

Analog Input Module provides sixteen channels 

for receiving 0-20mA signals for use with the 

Productivity2000 System.

Warning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Connector Specifications . . . . . . . . . . . . . . . . . . . . . 1

General Specifications   . . . . . . . . . . . . . . . . . . . . . . 2

Input Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . 2

Wiring Diagram and Schematic . . . . . . . . . . . . . . . . 3

Module Installation Procedure . . . . . . . . . . . . . . . . . 4

QR Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Hot Swap Information  . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Module Configuration   . . . . . . . . . . . . . . . . . . . . . . . 5

Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Non-Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . 6

Diagnostic/Status. . . . . . . . . . . . . . . . . . . . . . . . . . .  8

Summary of Contents for Productivity2000 P2-16ADL-1

Page 1: ...ave any questions concerning the installation or operation of this equipment or if you need additional information please call Technical Support at 770 844 4200 This publication is based on informatio...

Page 2: ...1010 2 201 Safety Input Specifications Input Channels 16 Module Signal Input Range 0 20 mA Signal Resolution 13 bit Resolution Value of LSB least significant bit 0 20 mA 2 44 A per count 1 LSB 1 count...

Page 3: ...ower User Supplied Transmitter Power AC or DC 032A fuse COM I 3 Wire Current Transmitter 3 Wire Transmitter 24VDC User Supplied Power COM Wiring Diagram Schematic 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1...

Page 4: ...your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot s...

Page 5: ...24 1P ZL P2 CBL24 2P 3Accessories ZL RTB COM TW SD SL 1 TW SD MSL 1 Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software drag and drop the P2 16ADL...

Page 6: ...2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Enter values for each breakpoint in the table Each breakpoint will define a segment of the non linear scaling 7 6 5 4 3 2 1...

Page 7: ...7 Sales 800 633 0405 www productivity2000 com...

Page 8: ...vision Date P2 16ADL 1 DS 2nd Ed Rev A 2 11 2022 Copyright 2015 AutomationDirect com Incorporated All Rights Reserved Worldwide Diagnostic Status Under Range Error 1 bit per channel Over Range Error 1...