DPM3-E Electrical User Manual, 1st Edition
User Manual - DPM3-E Series Electrical Panel Meters
16
Round
01
05
10
Will take each one of the values by pressing successively on the
SHIFT
key. with 01 there will be
no round, 05 will round the display value at 0 to 5, and with 10 will round at 0 to 10.
Brightness
HI
Lo
Display brightness level selection.
Hi:
high brightness
Lo:
low brightness
Display color selection between green, red or amber is possible for both
RUN
and
Pro
modes.
Eco
on off
Allows choosing an operative mode with an up to 45% of ENERGY SAVING*
on:
After a programmable time without pressing any key, display will turn off leaving only the
right decimal point flashing; all functions remain active. Display will be again active after
pressing any key.
oFF:
Deactivates the function.
* Measured at 230V AC power supply, display 100.00, amber colour and with no options.
Additional Functions
Several functions can be controlled via Key Pad that will produce different actions depending
on the instrument operating mode:
MAX/MIN function
With the meter in
RUN
mode: Activated after pressing the
SHIFT
key. From
RUN
mode, a
press shows the maximum value (peak) read by the instrument since the last time it has been
switched on, unless a
RESET MAX/MIN
is done, the
MAX
led will light up. A second press
shows the minimum value in the same conditions as before, with the consequent minimum
(valley) indication through the
MIN
led. A third press brings the instrument back to
RUN
mode.
Reset MAX/MIN
With the meter in
RUN
mode: Pressing the
SHIFT
key for 3 seconds, while the meter shows
the peak value
(MAX)
, will produce a reset of the value. Pressing
SHIFT
key for 3 seconds while
the meter shows the valley value
(MIN)
will produce a reset of the value.