background image

-|Transparent Guide|-

20220119

Remote I/O Boxes

(PROFINET)

ADIO-PN

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product
improvement. Some models may be discontinued without notice.

Features

• 

The upper level communication protocol: PROFINET

• 

The lower level communication protocol: IO-Link ver. 1.1 (port class: Class A)

• 

Housing material: Zinc Die casting

• 

Protection rating: IP67

• 

The daisy chain allows the power supply using the connection technology 

 

in a standardized 7/8” connector

• 

The maximum output current of power supply: 2 A per port

• 

I/O port settings and status monitoring 

 

(cable short / disconnection, connection status, etc.)

• 

Supports digital input filter

ᜢ ᜨ ᜣ ᜬ 

 

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery 

that may cause serious injury or substantial economic loss.(e.g. nuclear 

power control, medical equipment, ships, vehicles, railways, aircraft, 

combustion apparatus, safety equipment, crime/disaster prevention 

devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or 

fire.

02. 

Do not use the unit in the place where flammable/explosive/corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact or salinity 

may be present.

Failure to follow this instruction may result in explosion or fire.

03. Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire.

04. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

05. Do not disassemble or modify the unit. 

Failure to follow this instruction may result in fire.

06. 

Do not touch the product during operation or for a certain period of time 

after stopping.

 

Failure to follow this instruction may result in burn.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or shortening the life cycle of the 

product.

02. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

03. 

Keep the product away from metal chip, dust, and wire residue which flow 

into the unit. 

Failure to follow this instruction may result in fire or product damage.

 

04. Connect the cable correctly and prevent poor contact.

Failure to follow this instruction may result in fire or product damage.

05. 

Do not connect or cut off the wire of the cable while operating the unit.

Failure to follow this instruction may result in fire or product damage.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected 

accidents.

• 

The UA power (actuator power) and US power (sensor power) should be insulated by 

the individually isolated power device.

• 

Power supply should be insulated and limited voltage/current or Class 2, SELV power 

supply device. 

• 

Use the rated standard cables and connectors. Do not apply excessive power when 

connecting or disconnecting the connectors of the product.

• 

Keep away from high voltage lines or power lines to prevent inductive noise.

 

In case installing power line and input signal line closely, use line filter or varistor at 

power line and shielded wire at input signal line.

 

For stable operation, use shield wire and ferrite core, when wiring communication wire, 

power wire, or signal wire.

• 

Do not use near the equipment which generates strong magnetic force or high 

frequency noise.

• 

Do not connect, or remove this unit while connected to a power source.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 2

 

- Installation category II

Summary of Contents for ADIO-PN

Page 1: ...dify the unit Failure to follow this instruction may result in fire 06 Do not touch the product during operation or for a certain period of time after stopping Failure to follow this instruction may result in burn Caution Failure to follow instructions may result in injury or product damage 01 Use the unit within the rated specifications Failure to follow this instruction may result in fire or sho...

Page 2: ...ADIO PN Integrate the ADIO PN to PROFINET project ADIO PN TIA Portal V16Guide 01 Set the ports of ADIO PN Checking the operation Check the indicators ADIO PN Product Manual 01 The project planning software of the upper level communication system may be different depending on the user s environment For more information refer to the manufacturer s manual Operation mode Safe State01 Validation Data S...

Page 3: ... 4 1 TX Transmit Data 2 RX Receive Data 3 TX Transmit Data 4 RX Receive Data Power supply port OUT 7 8 Socket Female IN 7 8 Plug Male Pin Function Description 1 2 3 4 5 5 4 3 2 1 1 2 0 V Sensor and actuator supply 3 F G Frame ground 4 24 VDCᜡ Sensor supply 5 24 VDCᜡ Actuator supply PDCT port M12 Socket Female A coded Pin Function 1 4 5 3 2 1 Not Connected N C 2 Data 3 0 V 4 Not Connected N C 5 Dat...

Page 4: ...ide 29 6 4 7 1 3 215 24 26 5 26 5 26 5 35 26 Ø4 5 7 8 X 2EA 203 35 20 38 6 3 1 3 8 35 33 4 30 5 M4 X 0 7 Ø4 5 M12 X 1 X 11EA 66 Dimensions Unit mm For the detailed dimensions of the product follow the Autonics website ...

Page 5: ... Prepare a flat or metal panel in the enclosure 02 Drill a hole to mount and ground the product on the surface 03 Turn off all power 04 Fix the product using M4 screws in the mounting holes Tightening torque 1 5 N m M4 M4 Installation UnitDescriptions 1 2 3 2 4 4 5 5 6 7 9 10 8 01 Grounding hole 02 Mounting hole 03 Insertion part for the name plate 04 Ethernet port 05 Power supply port 06 PDCT por...

Page 6: ...y switches Description Value PROFINET Device Name 000 This device name is stored in the ADIO PN s EEPROM Applying the device name configured on the PROFINET Master or DCP tools PROFINET device name 001 to 999 Establish the communication connection after setting the ADIO PN s device name The value of rotary switches is displayed at the last of the device name ADIO PN MA08A ILM 02 Turn on the ADIO P...

Page 7: ...tor 1 Function Connector 2 Pin no Connector 2 Function 1 N C 1 5 VDCᜡ 2 Data 2 Data 3 0 V 4 0 V 4 N C 5 Data 3 Data 01 Connect to the PROFINET 01 Connect the M12 connector to the Ethernet port See the connections below 1 2 3 4 1 TX Transmit Data 2 RX Receive Data 3 TX Transmit Data 4 RX Receive Data 02 Connect the connector to the PROFINET network Network device PLC or PROFINET device supporting P...

Page 8: ... 24 VDCᜡ Sensor supply 5 24 VDCᜡ Actuator supply 1 2 3 4 5 5 4 3 2 1 PWR OUT PWR IN PortConnections 03 Connect with the atIOLink Do not use the PDCT port and the Ethernet port at the same time 01 Connect the M12 connector to the PDCT port See the connections below 1 4 5 3 2 1 Not Connected N C 2 Data 3 0 V 4 Not Connected N C 5 Data 02 Connect the connector to the network device Network device PC ...

Page 9: ...ngs of the rotary switches is changing Red Flashing 1 Hz Applied voltage low 18 VDCᜡ 02 The power supply of actuator Indicator LED color Status Description UA Green ON Applied voltage normal Red Flashing 1 Hz Applied voltage low 18 VDCᜡ Error in the rotary switches ON Applied voltage none 10 VDCᜡ 03 Product initialization Indicator LED color Status Description US UA Red ON ADIO initialization fail...

Page 10: ... 4 W 216 W Supplying current per port 2 A Port Sensor current US 9 A Dimensions W 66 H 215 D 38 mm Material Zinc Die casting Ethernet port M12 Socket Female 4 pin D coded Push Pull Number of ports 2 IN OUT Supported function daisy chain Power supply port Input 7 8 Plug Male 5 pin Output 7 8 Socket Female 5 pin Number of ports 2 IN OUT Supported function daisy chain PDCT port M12 Socket Female 5 pi...

Reviews: