7 Counter Mode
© Copyright Reserved Autonics Co., Ltd.
43
7
Counter Mode
7.1
Parameter Setting
(
key: Moves parameters,
,
key: changes parameter setting value)
Parameter
Parameter setting value
Counter/Timer
[
C-T
]
※
COUN
: Counter
TIME
:
Timer
Input mode
[
IN
]
Output mode
[
OUtM
]
●
Input mode is
UP
,
UP-1
,
UP-2
or
DN
,
DN-1
,
DN-2
,
●
Input mode is
UD-A
,
UD-B
,
UD-C
,
※
If max. counting speed is 5kcps or 10kcps, and output mode is
D
,
max. counting speed is automatically changed as 30cps, factory default.
Indication mode
[
DSpM
]
●
In case of indicator model,
※
In case of the indicator type, indicate mode selection [
DSP. M
] is displayed.
※
It is the added function to set the setting value when selecting
HOLD
.
Max. counting
speed [
CPS
]
※
Max. counting speed is when duty ratio of INA or INB input signal is 1:1.
It is applied for INA, or INB input as same.
※
When output mode is
D
, set max. counting speed one among 1cps, 30cps, or
1kcps.
OUT2 output
time
※
1
[
OUT2
]
※
Set one-shot output time of OUT2.
※
Setting range: 0.01 to 99.99 sec
※
When output mode is
F
,
N
,
S
,
T
,
D
,
OUT2
does not appear.
(fixed as HOLD)
OUT1 output
time
※
1
[
OUT1
]
※
Set one-shot output time of OUT1.
※
Setting range: 0.01 to 99.99 sec, Hold
※
When 1st digit is flashing, press the
key once and
HOLD
appears.
※
When output mode is
S
,
T
,
D
,
OUT1
does not appear. (fixed as HOLD)
OUT output
time
※
1
[
OUtT
]
※
Setting range: 0.01 to 99.99 sec
※
When output mode is
F
,
N
,
S
,
T
,
D
,
OUtT
does not appear. (fixed as HOLD)
Decimal point
※
2
[
DP
]
●
6-digit model
●
4-digit model
※
Decimal point is applied to counting value and setting value.
Summary of Contents for CT4S-2P series
Page 1: ...Programmable Counter Timer User Manual CT Series CT Series CT Series ...
Page 2: ...내 ii Copyright Reserved Autonics Co Ltd ...
Page 8: ...Cautions During Use 나 viii Copyright Reserved Autonics Co Ltd ...
Page 16: ...1 Product Overview 16 Copyright Reserved Autonics Co Ltd ...
Page 20: ...3 Communication Specification 20 Copyright Reserved Autonics Co Ltd ...
Page 24: ...4 Dimensions 24 Copyright Reserved Autonics Co Ltd ...
Page 36: ...5 Guide For Connection 36 Copyright Reserved Autonics Co Ltd ...
Page 42: ...6 Basic Operations Counter Timer Communication 42 Copyright Reserved Autonics Co Ltd ...