8 Timer Mode
56
© Copyright Reserved Autonics Co., Ltd.
Parameter
Parameter setting value
OUT2 output
time
※
1
[
OUT2
]
※
Set one-shot output time of OUT2.
※
Setting range: 0.01 to 99.99 sec, Hold
※
When 1st digit is flashing, press the
key once and
HOLD
appears.
OUT1 output
time
※
1
[
OUT1
]
※
Set one-shot output time of OUT1.
※
Setting range: 0.01 to 99.99 sec, Hold
※
When 1st digit is flashing, press the
key once and
HOLD
appears.
OUT output
time
※
1
[
OUtT
]
※
Setting range: 0.01 to 99.99 sec, Hold
※
When 1st digit is flashing, press the
key once and
HOLD
appears.
Input logic
[
SIG
]
NPN
: no-voltage input,
PNP
: voltage input
※
Check input logic value (NPN, PNP).
Input signal
time
[
InT
]
, unit: ms
※
CTS/CTY: Set min. width of INA, INH, RESET signal.
※
CTM: Set min. width of INA, RESET, INHIBIT, BATCH RESET signal.
Key lock [
LOCK
]
※
lOFF
: Unlock keys, key lock indicator turns OFF
LOc1
: Locks
key, key lock indicator turns ON
LOc2
: Locks
,
,
keys, key lock indicator turns ON
LOc3
: Locks
,
,
,
keys, key lock indicator turns ON
※
1: When output mode is
FLk1
,
FLk2
,
INTG
and
OND
,
ONd1
,
ONd2
of 1-stage setting value
change model,
OUT1
does not appear. The output time of
OUT2
is displayed as
OUtT
.
When output mode is
OND
,
ONd1
,
ONd2
,
INt2
,
OUT1
appears.
※
2:
INt2
mode is available only for 2-stage setting value change model.
Summary of Contents for CT4S-2P series
Page 1: ...Programmable Counter Timer User Manual CT Series CT Series CT Series ...
Page 2: ...내 ii Copyright Reserved Autonics Co Ltd ...
Page 8: ...Cautions During Use 나 viii Copyright Reserved Autonics Co Ltd ...
Page 16: ...1 Product Overview 16 Copyright Reserved Autonics Co Ltd ...
Page 20: ...3 Communication Specification 20 Copyright Reserved Autonics Co Ltd ...
Page 24: ...4 Dimensions 24 Copyright Reserved Autonics Co Ltd ...
Page 36: ...5 Guide For Connection 36 Copyright Reserved Autonics Co Ltd ...
Page 42: ...6 Basic Operations Counter Timer Communication 42 Copyright Reserved Autonics Co Ltd ...