Specifications

 

Features

DIN W72×H36mm Of Counter/Timer With Indication Only

 

Model

Please read “Safety Considerations” in operation 

manual before using.

Model

Indicator

FX4Y-I2

FX4Y-I4

FX6Y-I2

FX6Y-I4

Display digit

4-digit

6-digit

Character size (W×H)

8×14mm

4×8mm

Power supply

24VAC~ 50/60Hz,

24-48VDC

З

100-240VAC~ 50/60Hz

24VAC~ 50/60Hz,

24-48VDC

З

100-240VAC~ 50/60Hz

Permissible voltage range

90 to 110% of rated voltage

Power consumption

Max. 2.8VA 

(24VAC~ 50/60Hz), 

Max. 1.8W (24-48VDC

З

)

Max. 3.8VA 

(240VAC~ 50/60Hz)

Max. 2.8VA 

(24VAC~ 50/60Hz), 

Max. 1.8W (24-48VDC

З

)

Max. 3.8VA 

(240VAC~ 50/60Hz)

Max. counting speed of CP1/CP2 Selectable 1cps/30cps/2kcps/5kcps (DIP switch)
Return time

Max. 500ms

Min. signal width

INHIBIT, RESET: approx. 20ms

Input method

Selectable voltage input (PNP) method or no-voltage input (NPN) method

[Voltage input (PNP) method]-input impedance: max. 10.8k

Ω, [H]: 5-30VDC

З

, [L]:0-2VDC

[No-voltage input (NPN) method]-short-circuit impedance: max. 470Ω, short-circuit residual voltage: max. 1VDC,

                                                      

 

open-circuit impedance: min. 100kΩ

Repeat/Set/Voltage/Temp. error Max. ±0.01% ±0.05 sec
Insulation resistance

Over 100MΩ (at 500VDC megger)

External power supply

Max. 12VDC

З

 ±10% 50mA

Memory retention

Approx. 10 years (non-volatile memory)

Dielectric strength

2,000VAC 50/60Hz for 1 min (between all terminals and case)

Noise 

immunity

AC voltage

±2kV the square wave noise (pulse width 1μs) by noise simulator

AC/DC voltage

±500V the square wave noise (pulse width 1μs) by noise simulator

Vibration

Mechanical

0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour

Malfunction

0.5mm amplitude at frequency 10 to 55Hz (for 1 min)  in each X, Y, Z direction for 10 minutes

Shock

Mechanical

300m/s

2

 (approx. 30G) in each X, Y, Z direction for 3 times

Malfunction

100m/s

2

 (approx. 10G) in each X, Y, Z direction for 3 times

Environment

Ambient temp. -10 to 55

, storage: -25 to 65

Ambient humi. 35 to 85%RH, storage: 35 to 85%RH

Protection structure

IP40 (front part, IEC standard)

Approval
Weight

1

Approx. 175g (approx. 120g)

1: The weight includes packaging. The weight in parenthesis is for unit only.     

Environment resistance is rated at no freezing or condensation. 

● Counting speed: 1cps/30cps/2kcps/5kcps

● Selectable voltage input (PNP) method or 

   

 

no-voltage input (NPN) method

● Input mode: Up, Down, Up/Down

● Dot for Decimal Point / Hour. Min. Second by RESET key

● Wide range of input power supply

    :  100-240VAC 50/60Hz,  

24VAC 50/60Hz, 24-48VDC universal 

● Selectable Counter or Timer function by internal DIP switch

● Changed case color (ivory → 

black)

● [Counter]

   20 input modes

● 

[Timer] 

   Various time setting range-6-digit model: 0.01 sec to 99999.9 hour / 

                                             

 

4-digit model: 0.01 sec to 9999 hour

● Output: Indicator

Model

Display digit

Size

Output

Power supply

FX4Y-I2

9999 (4-digit)

DIN W72×H36mm

Indicator

24VAC 50/60Hz, 24-48VDC

FX4Y-I4

100-240VAC 50/60Hz

FX6Y-I2

999999 (6-digit)

24VAC 50/60Hz, 24-48VDC

FX6Y-I4

100-240VAC 50/60Hz

Summary of Contents for FXY Series

Page 1: ...re wave noise pulse width 1μs by noise simulator AC DC voltage 500V the square wave noise pulse width 1μs by noise simulator Vibration Mechanical 0 75mm amplitude at frequency 10 to 55Hz for 1 min in each X Y Z direction for 1 hour Malfunction 0 5mm amplitude at frequency 10 to 55Hz for 1 min in each X Y Z direction for 10 minutes Shock Mechanical 300m s2 approx 30G in each X Y Z direction for 3 t...

Page 2: ...P connect with 12VDC no voltage input NPN connect with 0VDC Dimensions unit mm Counting Method NPN output type Proximity sensor When the sensor is changed from OFF to ON it counts PNP output type Proximity sensor When the sensor is changed from ON to OFF it counts Be careful to select sensor because the counting method of NPN output type sensor is different from PNP output type sensor Target Targe...

Page 3: ...t input Input Connections CP1 CP2 INHIBIT RESET input part Sensor Brown Brown Black Black Blue Blue 12V 12V Inner circuit Inner circuit 10 8kΩ 10 8kΩ 0V 0V Sensor Counter Timer PNP output PNP open collector output Counter Timer 12V Inner circuit 10 8kΩ 0V Counter Timer Counting speed Set as 1 or 30cps No voltage input NPN Voltage input PNP Counting operation Time operation Sensor Brown Black Blue ...

Page 4: ...99hour 99999 9hour OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 DIP Switch Setting SW Function OFF ON 5 6 1cps OFF ON 5 6 30cps OFF ON 5 6 2kcps OFF ON 5 6 5kcps SW 2 3 4 5 6 7 8 9 10 Time range timer Input operation mode counter Up Down mode Max counting speed counter Available Unavailable front RESET key Memory backup Counter Timer Input...

Page 5: ... L L L H H H H H L L L L L L L H H H H H H H H H H H H H H H H H H H H H H H H H H H H A A A A A A A A A A A A A A A A A A A A No counting No counting No counting 0 0 n n n n n n n n n n 0 0 0 0 0 0 0 0 0 0 n 1 n 1 n 1 n 1 n 1 n 1 n 2 n 3 n 2 n 1 n 2 n 3 n 2 n 3 n 2 n 2 n 3 n 1 n 1 n 1 n 2 n 2 n 2 n 2 n 3 n 3 n 3 n 4 n 5 n 2 n 3 n 4 n 5 n 2 n 3 n 1 n 1 n 1 n 1 n 2 n 3 n 2 n 1 n 2 n 3 n 2 n 2 n 1 n...

Page 6: ...power In case of contact input set count speed to low speed mode 1cps or 30cps to operate If set to high speed mode 2kcps or 5kcps counting error occurs due to chattering Keep away from high voltage lines or power lines to prevent inductive noise In case installing power line and input signal line closely use line filter or varistor at power line and shielded wire at input signal line Do not use n...

Reviews: