background image

J-40

FXY Series

 Input Operation Mode (Counter)

Input mode

SW

Voltage input (PNP) method

No-voltage input (PNP) method

Up 

mode

OFF
ON

4

Up/

Down-A

(command 

input)

OFF
ON

2  3

Up/

Down-B

(individual 

input)

OFF
ON

2  3

Up/

Down-C

(phase 

difference 

input)

OFF
ON

2  3

Up

(adding 

input)

OFF
ON

2  3

 

Down 

mode

OFF
ON

4

Up/

Down-D

(command 

input)

OFF
ON

2  3

Up/

Down-E

(individual 

input)

OFF
ON

2  3

Up/

Down-F

(phase 

difference 

input)

OFF
ON

2  3

 

Down

(subtracting

input)

OFF
ON

2  3

H

H

H

H

H

H

H

A

A

0

0

0

0

0

0

1

1

1

1

1

1

2

2

2

2

2

2

3

3

3

3

3

3

2

2

2

2

2

2

1

1

1

1

1

1

1

1

2

2

2

2

2

2

3

3

3

3

3

3

A

BBBB

A

CP1

CP1

CP1

CP1

CP2

CP1

CP1

CP2

CP2

CP2

CP2

CP2

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

Count

L

L

L

L

L

H

H

H

H

H

L

L

L

L

L

L

L

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

H

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

No counting

No counting

No counting

0

0

n

n

n

n

n

n

n

n

n

n

0

0

0

0

0

0

0

0

0

0

n-1

n-1

n-1

n-1

n-1

n-1 n-2

n-3 n-2

n-1 n-2

n-3

n-2 n-3 n-2

n-2 n-3

n-1 n-1

n-1

n-2

n-2

n-2

n-2

n-3

n-3

n-3

n-4 n-5

n-2

n-3 n-4

n-5

n-2

n-3

n-1

n-1

n-1

n-1 n-2

n-3 n-2

n-1 n-2

n-3

n-2

n-2 n-1 n-1 n-2 n-3

n-3

n-2 n-3 n-2 n-1 n-2 n-3

n-2

n-3

n-4 n-5

n-4 n-5

0

0

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP2

CP2

CP2

CP2

CP2

CP2

CP2

CP2

CP2

CP2

CP1

CP1

CP2

CP2

CP2

CP2

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

BBBB

BBBB

No counting

No counting

No counting

No counting

BBBB

No counting

CP: Clock Pulse

A: over min. signal width, B: over than 1/2 of min. signal width. If the signal is smaller than these width, it may cause 

counting error (±1).

n: +Max. display value (FX4Y-I: 9999, FX6Y-I: 999999)

Summary of Contents for FXY Series

Page 1: ...re wave noise pulse width 1μs by noise simulator AC DC voltage 500V the square wave noise pulse width 1μs by noise simulator Vibration Mechanical 0 75mm amplitude at frequency 10 to 55Hz for 1 min in each X Y Z direction for 1 hour Malfunction 0 5mm amplitude at frequency 10 to 55Hz for 1 min in each X Y Z direction for 10 minutes Shock Mechanical 300m s2 approx 30G in each X Y Z direction for 3 t...

Page 2: ...P connect with 12VDC no voltage input NPN connect with 0VDC Dimensions unit mm Counting Method NPN output type Proximity sensor When the sensor is changed from OFF to ON it counts PNP output type Proximity sensor When the sensor is changed from ON to OFF it counts Be careful to select sensor because the counting method of NPN output type sensor is different from PNP output type sensor Target Targe...

Page 3: ...t input Input Connections CP1 CP2 INHIBIT RESET input part Sensor Brown Brown Black Black Blue Blue 12V 12V Inner circuit Inner circuit 10 8kΩ 10 8kΩ 0V 0V Sensor Counter Timer PNP output PNP open collector output Counter Timer 12V Inner circuit 10 8kΩ 0V Counter Timer Counting speed Set as 1 or 30cps No voltage input NPN Voltage input PNP Counting operation Time operation Sensor Brown Black Blue ...

Page 4: ...99hour 99999 9hour OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 DIP Switch Setting SW Function OFF ON 5 6 1cps OFF ON 5 6 30cps OFF ON 5 6 2kcps OFF ON 5 6 5kcps SW 2 3 4 5 6 7 8 9 10 Time range timer Input operation mode counter Up Down mode Max counting speed counter Available Unavailable front RESET key Memory backup Counter Timer Input...

Page 5: ... L L L H H H H H L L L L L L L H H H H H H H H H H H H H H H H H H H H H H H H H H H H A A A A A A A A A A A A A A A A A A A A No counting No counting No counting 0 0 n n n n n n n n n n 0 0 0 0 0 0 0 0 0 0 n 1 n 1 n 1 n 1 n 1 n 1 n 2 n 3 n 2 n 1 n 2 n 3 n 2 n 3 n 2 n 2 n 3 n 1 n 1 n 1 n 2 n 2 n 2 n 2 n 3 n 3 n 3 n 4 n 5 n 2 n 3 n 4 n 5 n 2 n 3 n 1 n 1 n 1 n 1 n 2 n 3 n 2 n 1 n 2 n 3 n 2 n 2 n 1 n...

Page 6: ...power In case of contact input set count speed to low speed mode 1cps or 30cps to operate If set to high speed mode 2kcps or 5kcps counting error occurs due to chattering Keep away from high voltage lines or power lines to prevent inductive noise In case installing power line and input signal line closely use line filter or varistor at power line and shielded wire at input signal line Do not use n...