■ F9: length measurement

 1

Measure and display the number of input A pulses during input B ON.

Length measurement

 1

= P × α 

• 

P: number of input A pulses

• 

α: prescale

 

value

Display value Display

 unit

Length 

measurement

 

1

Quantity [EA]

(

default)

mm

cm

m

Photoelectric sensor

Input A

Input B

MP5

Input A

Input B

Display

Hold

1

5

2

3

3

1

2

6

ta

tb

6 × α

2 × α

4 × α

4

4

1

2

• 

ta, tb: Return time (≥ 20 ms)

  

F10: 

interval

Measures and displays the number of input A pulses from input B ON to the next 

ON.

Interval

= P × α 

• 

P: number of input A pulses

• 

α: prescale

 

value

Display value Display

 unit

Interval

Quantity [EA]

(

default)

mm

cm

m

Photoelectric sensor

MP5

1

1

1

5

3

3

3

2

2

2

4

4

ta

Input A

Input B

Display

Hold

5 × α

4 × α

• 

ta: Return time (≥ 20 ms)

  

F11: accumulation

Measures and displays the counted value of input A pulses.

Accumulation = P × α 

• 

P: number of input A pulses

• 

α: prescale

 

value

Display value Display

 unit

Accumulation Quantity [EA]

MP5

• 

Operation

① Counts the number of input A pulses. 

②  Input B is an enable input signal. During ON, the quantity and display value of input A 

will be held, and during OFF input A will be recounted.

③  When RESET input is ON, the integrated counted value will be reset to “0”

• 

α = display value for 1 

Input A

Input B

RESET

Display

1

0

0

1

1

2

2

3

3

4

4

5

5

3

3

1

2

6

6

4

4

2

  

F12: 

addition / subtraction

-in

dividual input

Displays the counted value from added input A pulses and subtracted input B 

pulses. When there are two inputs simultaneously, it will not count.

Add / Sub

 

(

individual)

= input A × α - input B × α 

• 

α: prescale

 

value of  input A

Display value

Display

 unit

Addition / 

Subtraction

 

(

individual)

Quantity [EA]

Photoelectric 

sensor

Input A

 

(

add)

Input B

 

(

sub)

MP5

Input A

Input B

RESET

Display

0

0

1

2

2

2

2

3

1

1

3

• 

α = display value for 1 

  

F13: 

addition / subtraction

-

phase difference input

When input A is Low, counting is added to the low of input B.

When input A is Low, counting is subtracted from the high of input B.

Add / Sub

  

(phase difference)

=  Detects position and speed 

using A and B phases of 

encoder outputs as input.

Input A

Input B

MP5

Display value

Display

 unit

Addition / 

Subtraction

 

(phase difference)

Quantity [EA]

Input A

Input B

RESET

Display

0

0

1

1

1

2

2

2

3

0

  

F14: 

length measurement

 2

Measures and displays the number of pulses from input A until the value of input B 

reaches the setting value.

Length 

measurement 2

= P × α (until the setting 

 

value of input B)

• 

 P: number of input A pulses

• 

α: prescale

 

value

Display value

Display

 unit

Length 

measurement 2

Quantity [EA]

• 

If input A and input B are ON during initial power supply, it will not count and only count the 
number of rising edge.

• 

Display value is renewed depending on the P2-9. Display

 

cycle. 

01)  When P2-9 Display cycle is OFF, it will maintain the quantity of input A until the value of 

input B reaches the setting value of P2-10 Input B setting value (INB).

 (

e.g.: input B = 4)

Input A

Input B

Display
Display

 

01)

1

1

1

2

4

1

1

3

3

2

2

2

2

1

0

0

3

3

2

4

4

3

0

0

5

4

5

6

7

7

RESET

Summary of Contents for MP5M Series

Page 1: ...ce panel to use Failure to follow this instruction may result in fire or electric shock 04 Do not connect repair or inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock 05 Check Connections before wiring Failure to follow this instruction may result in fire 06 Do not disassemble or modify the unit Failure to follow this instruct...

Page 2: ...range F S 0 01 rdg 1 digit F4 Passing time F5 Time interval F6 Time differential F7 Absolute ratio 0 0005 Hz to 50 kHz F S 0 05 rdg 1 digit F8 Density F9 Length measurement 1 0 to 99999 F10 Interval F11 Accumulation F12 Addition subtraction individual input 19999 to 99999 F13 Addition subtraction phase difference input F14 Length measurement 2 0 to 99999 Specifications Series MP5M N MP5M 1 MP5M 2 ...

Page 3: ... 9999 9 sec P1 1 Input operation mode F1 F4 F7 to 8 P1 9 Input B auto zero time AUToB 999 9 P1 1 Input operation mode F7 to 8 P1 10 Memory retention MEMO OFF OFF ON P1 1 Input operation mode F11 to 14 01 In case of P1 1 Input operation mode F13 input B sensor type is not displayed and IN B setting is same as IN A 02 key Entering compensation time setting Parameter 1 group OutputMode Output mode is...

Page 4: ...ault 999 99 m 9999 9 s 9999 9 m 99999 s 99999 m MP5 L Distance m Input A t1 t1 α t2 α t5 α t2 t3 α t6 α t3 t4 t5 t6 Hold Display F5 time interval Displays measured time of input A ON Time interval T t t measured time of input A ON sec Display value Display unit Time interval SEC MIN 999 99 s default 999 99 m 9999 9 s 9999 9 m 99999 s 99999 m Stamp Motor MP5 ta Return time 20 ms Input A t1 t1 t2 t2...

Page 5: ...d input A pulses and subtracted input B pulses When there are two inputs simultaneously it will not count Add Sub individual input A α input B α α prescale value of input A Display value Display unit Addition Subtraction individual Quantity EA Photoelectric sensor InputA add InputB sub MP5 Input A Input B RESET Display 0 0 1 2 2 2 2 3 1 1 3 α display value for 1 F13 addition subtraction phase diff...

Page 6: ...r than the interval of the slowest input signal If the setting time is too long and there is no input signal the rate at which the display value falls to 0 zero decrease and output response rate may slow down Prescale Displays values in required units or specific multiples by counting the number of input pulses then multiplying the number of pulses or the length of pulses by variables X 10y E g pr...

Reviews: