Diagnostics – Parking Light Flash Table 

Flashes 

Description 

 

Doors locked, Starter Kill armed. 

 

End of Run Time. 

 

TRUNK

 button pressed 

 

Start signal received by the Remote Car Starter. 

 

Cold Weather Mode cancelled. 

 

Cannot start after maximum number of attempts is reached. 

 

Doors unlocked, Starter Kill disarmed.  

 

Remote start attempt cancelled by remote.  

 

Entering 

Cold Weather Mode

 

Entering or Exiting 

Ready Mode

 

Entering Extended Run Time. 

 

+12 V where detected on the brake line and cranking was cancelled. 

 

Entering Tach-programming Mode 

 

New Transmitter programmed. 

 

Tach programmed. 

 

A remote start was attempted while a Tach or a vacuum signal was detected 

before cranking. 

 

Unit reset: occurs when the Unit is reset to the factory defaults. 

10 

 

The Hood Switch line went to ground during cranking or Run Time. 

1 – pause – 2 

 

There was an attempt to start the vehicle while the Remote Car Starter was 

in Valet Mode. 

2 – pause – 2 

 

There was an attempt to start the vehicle while the Remote Car Starter was 

in Home Valet Mode. 

4 – pause – 3 

 

The vehicle went out of Ready Mode: +12 V detected on the Brake Line. 

10 – pause – 3 

 

The vehicle went out of Ready Mode: the Hood Pin-switch went to ground. 

ON 2 sec. 

 

The Hood is up and the Hood Switch line went to ground. This is step one of 

the Programming Centre procedure. 

ON 3 sec. 

 

First press of the 

START

 button under Safe Start. 

ON 4 sec. 

 

Locking or unlocking a Door (with Door pulses configured to 4 sec.) 

ON 25 sec. 

 

The Hood Pin-switch has been pressed twice: the Unit went into step 1 of the 

Programming Centre procedure, and no Transmitter activity was detected for 

20 seconds. 

 

Or 

the Unit went into step 1 of the Transmitter Programming procedure and 

no activity was detected for a few seconds. The Unit has exited the 

Transmitter Programming procedure.

 

Irregular 

 

If the unit gives irregular signals (1 to 10 flashes followed by a pause, 

followed by further flashes), the system is playing back Start Failure Codes. 

This occurs when the Hood Pin-switch is pressed three times

.

 

Constant 

flashes 

up to 30 sec. 

 

Panic Mode was triggered. 

 

Summary of Contents for AS-1785

Page 1: ...supplied Please note that this guide has been written for properly trained Autostart technicians a certain level of skills and knowledge is therefore assumed Please review the Installation Guide carefully before beginning any work Warning This Remote Car Starter is designed for vehicles with a manual Transmission only Before installing the Unit test that the OEM Door Switch contacts of the vehicle...

Page 2: ... Starter Most of the features of this product are explained in the User Guide Therefore if you need detailed information about a feature of the product we recommend that you refer to the User Guide Included in the Kit Please carefully read the Installation Guide before beginning the installation especially the Harness Description section and the Programming Options It is very important that you fa...

Page 3: ...the vehicle to access the Hood Pin Switch The PAB works only when the Hood is up Inspect vehicle for any body damage or electrical problems Always solder and tape all connections Keep the Antenna away from other types of antennas GPS OnStar Never install the control unit where it could interfere with normal operation or obstruct service technicians Always use a grommet when running wires into the ...

Page 4: ...o put them back during the very last steps 6 Pin Main Ignition Harness Wire Colour Function Description Connect to the largest 12 V supply wire at the Ignition Harness Ensure that the OEM power wire is fused for more than 30 A A RED 12 V Battery Please note some of the most recent vehicles have no suitable 12 V source at the Ignition Switch the 12 V wire is too small to supply the necessary curren...

Page 5: ...cal system This high current output can be used to power a second Ignition Accessories or Crank wire See Jumper Setting later in this Guide for correct output F GREEN Fifth Relay output 30 A Please note additional Ignition Accessories or Starter wires must use external relays Do not jump wires at the Ignition Switch this would compromise the OEM electrical system 5 Pin Secondary Harness Wire Colou...

Page 6: ...ease or increase when the dimmer control switch is turned If the voltage goes up or down find another Parking Light wire 12 Pin Accessories Harness Wire Colour Function Description 1 BLUE Trunk AUX 3 output 500 mA negative output This output can be used to control the Trunk release 1 sec pulse or it can be set to operate as a constant output as long as the TRUNK button is held pressed for Sunroof ...

Page 7: ... by itself a sufficient connection 7 WHITE ORANGE Starter Kill output armed output This wire will provide a constant 500 mA output when the system is armed locked by remote control It can be connected to an external Starter Interrupt Relay This wire should be connected to a Single Pole Double Throw Relay this wire will connect to Pin 85 on the Relay and Pin 86 will be connected to the Ignition wir...

Page 8: ... enabled UNLOCK pulse s will be sent with DISARM a LOCK pulse and a REARM pulse will be sent when the Trunk is closed or if the Trunk was left closed Option 2 Default Engine Start Stop The first Ground pulse on this input will start the Engine the second Ground pulse on this input will stop the Engine Option 3 Key Sense Input Connects to OEM Key Sense Wire When the Key is detected in the Ignition ...

Page 9: ... essential that the Remote Car Starter be connected in such a way as will allow each one of the Doors to turn off Ready Mode the driver side Door Pin does not constitute by itself a sufficient connection 12 YELLOW Glow Plug input In Diesel Mode this positive input will monitor the Glow Plug Light it will wait for up to 18 seconds until the Glow plug Light goes out before allowing the Remote Car St...

Page 10: ...on The Remote Car Starter will only accept positive Glow plug input signals therefore negative Glow Plugs should only be connected using relays to invert the polarity A diode must be added between the negative Glow plug trigger on the relay and the negative Glow plug wire of the car This is to prevent feedback effects on the Glow plug indicator light on the instrument cluster the light on the dash...

Page 11: ... very last steps in the installation process 2 Pin Harness Wire Colour Function Description 1 BLUE WHITE AUX 2 output This 500 mA negative output can be programmed for one of the following Options Constant while the LOCK and UNLOCK buttons are pressed simultaneously 1 sec after the buttons are released Pressing LOCK and UNLOCK simultaneously toggles the output ON and OFF with automatic toggle OFF ...

Page 12: ...ave up to 20 seconds to select a sub menu If you do not select a sub menu within 20 seconds the Remote Car Starter will exit Programming Mode and you will have to flash the Hood Pin switch once again The Programming Assistance Button A k a the PAB Mounted on the Remote Car Starter this button can be used from within the vehicle instead of the Hood Pin switch in the Engine compartment This will spa...

Page 13: ...gramming Options are designed to facilitate interfacing with all vehicle types See section Table of Programming Options later in this Guide 1 Flash the Hood Pin switch see Table 1 The Parking Lights will stay ON for up to 20 seconds Before the lights go out 2 Press and hold the Brake Pedal And press one of the following buttons on the Transmitter LOCK to access Mode 1 UNLOCK to access Mode 2 TRUNK...

Page 14: ...NABLED in Standard Mode FUNCTION 3 Passive or Active Arming OPTION 1 PASSIVE Arming 60 sec OPTION 2 ACTIVE Arming OPTION 3 PASSIVE Arming 3 min FUNCTION 4 Door lock pulse timing OPTION 1 7 10 sec Lock Unlock pulses OPTION 2 4 sec Lock Unlock pulses OPTION 3 7 10 sec Lock pulse and two 1 4 sec Unlock pulses OPTION 4 1 10 sec Lock Unlock pulses FUNCTION 5 LED flashing OPTION 1 ENABLED without starte...

Page 15: ...Start Mode activate AUX 2 by pressing the START button OPTION 2 Toggle ON OFF with 30 second timeout OPTION 2 Horn confirmation when lock OPTION 4 Priority Door Access FUNCTION 5 External Trigger OPTION 1 Zone 3 disarm rearm Trunk Pin a disarm pulse is sent before the Trunk opens the vehicle rearms 4 seconds after the Trunk is closed OPTION 2 Engine Start Stop OPTION 3 Key Sense Tach Programming A...

Page 16: ...the Tach programming procedure Automatic Tach Programming This simple procedure can replace the Multi speed Tach Programming procedure 1 Make sure that all the connections are properly made and that the Remote Car Starter is powered up 2 With the Hood up ground on the Hood Pin switch line start the vehicle using the Key 3 Allow the vehicle to reach regular Engine idle speed The Parking Light outpu...

Page 17: ...ended to check that the system operates properly The following testing procedures should be used to verify proper installation and operation of the system Before testing make sure that all connections are soldered and that the unit is plugged in Make sure the Remote Car Starter properly enters and exits Ready Mode Setting the system to Ready Mode 1 Ensure that all the Doors are closed and that the...

Page 18: ...ction Door Pin shutdown circuit Make sure the Remote Car Starter exits Ready Mode when each Door is opened while the vehicle is running under a Remote Start Test each door OEM Alarm Control Make sure the Module is able to arm and disarm the OEM Alarm if applicable Door Locks and Trunk Testing Make sure each of these options respond to the Transmitter if installed Starter Kill option Sit inside the...

Page 19: ... A causing the 30 A Fuse to blow Always verify your circuit with an appropriate measuring device Clutch bypass In order to remote start a manual Transmission vehicle the Clutch switch must be bypassed Clutch safety switch circuits can take many forms The most common types are listed below When testing to determine the type of Clutch circuit it is recommended that you use a computer safe logic prob...

Page 20: ...stem when the clutch is pressed a negative signal is sent to the relay the relay energizes when the Key is turned to the START position the 12 V from the start wire is allowed to pass through the relay and to starter motor One of the wires at the clutch will test as negative this is the supply wire The relay s negative trigger wire will only show negative when the pedal is pressed some vehicle s a...

Page 21: ...e a relay to interrupt this wire during remote starts Ignition controlled Door Locks This feature will LOCK all the Doors of the vehicle when the Brake Pedal is pressed while the Ignition Key is in the IGNITION ON RUN position The unit will UNLOCK all Doors when the Ignition Key is turned back to the OFF position If Ignition Lock Only is selected the system will only LOCK all Doors when the Brake ...

Page 22: ...ked by remote control and can be connected to an external Starter or Ignition interrupt relay see diagram below The Starter Kill circuit can be set to arm in either Passive Mode or Active Mode Caution When installing the Starter Kill it is extremely important that pin 86 be wired to Ignition do not jump it to pin 30 damage to the vehicle could result Note Installation of the Starter Kill system re...

Page 23: ... this feature the Remote Car Starter will play back the last 4 Start Failure Events Codes and the last Intrusion Code via the Parking Lights or L E D Events playback Ensure that the Hood is up that the vehicle is not in Valet Mode and that the Ignition is OFF Hold down the Hood Pin switch for 4 seconds Release the Pin switch The Parking Lights will come on While the Parking Lights are on immediate...

Page 24: ... 2 pause 2 There was an attempt to start the vehicle while the Remote Car Starter was in Home Valet Mode 4 pause 3 The vehicle went out of Ready Mode 12 V detected on the Brake Line 10 pause 3 The vehicle went out of Ready Mode the Hood Pin switch went to ground ON 2 sec The Hood is up and the Hood Switch line went to ground This is step one of the Programming Centre procedure ON 3 sec First press...