background image

MODE 1

( * indicates default setting)

FUNCTION 1 – Ignition-controlled Door Locks 

OPTION 1* 

Ignition-controlled Door Locks 

ENABLED

OPTION 2

Ignition-controlled Door Locks

DISABLED

FUNCTION 2 – Secure Lock

OPTION 1* 

Secure Lock 

DISABLED

OPTION 2

Secure Lock

ENABLE

FUNCTION 3 – Passive / Active Arming of the Starter Kill 

OPTION 1* 

Starter Kill 

PASSIVE

(1-minute timeout.) 

OPTION 2 

Starter Kill 

ACTIVE

OPTION 3 

Starter Kill 

PASSIVE

 (3-minute timeout.) 

FUNCTION 4 – Lock Pulse Duration 

OPTION 1* 

7/10-second

LOCK / UNLOCK

 pulses 

OPTION 2 

4-second

LOCK / UNLOCK

 pulses

OPTION 3 

7/10-second

LOCK

 pulse and 

two

1/4-second

UNLOCK

 pulses

MODE 2

( * indicates default setting)

FUNCTION 1 – Engine Run Time 

OPTION 1 

4-minute Run Time in Gas Mode / 9-minute in Diesel Mode. 

OPTION 2*

15-minute Run Time in Gas Mode / 20-minute in Diesel Mode. 

OPTION 3 

25-minute Run Time in Gas Mode / 30-minute in Diesel Mode. 

FUNCTION 2 – Idle Mode 

OPTION 1 

Idle Mode 

DISABLED

OPTION 2* 

Idle Mode 

ENABLED

OPTION 3 

Idle Mode 

DISABLED

FUNCTION 3 – Engine Type – Gas or Diesel

OPTION 1 

DIESEL

 Engine Mode

OPTION 2* 

GASOLINE

Engine Mode

OPTION 3 

DIESEL

 Engine Mode

Installation-programmable Features 

The following features can be programmed according to the user’s needs and the requirements of the installation. 

Ignition-controlled Door Locks 

(Mode 1, Function 1: Option 1 –

ON

– by default.) 

This feature will automatically lock all Doors as soon as the key is 

turned to the 

IGNITION ON (RUN)

position, and the Brake Pedal is pressed. When the Ignition Key is turned to the 

OFF

position, the Doors will automatically be unlocked. 

Secure Lock 

(Mode 1, Function 2 , Option 1 – 

OFF

by default.) 

This feature allows the Module to control certain OEM factory Alarm 

systems that use the factory Lock wire to 

arm

the Alarm and the Unlock wire to 

disarm

it.

If Secure Lock is disabled (Option 1), the Module will still disarm before remote-starting the vehicle. If Secure Lock is
enabled (Option 2), upon receiving a remote 

START

 signal the Module will 

UNLOCK

 the Doors (disarming the factory 

Alarm); 1/2 sec. after remote start it will 

re-lock

the Doors. 4 seconds after shutdown, Secure Lock will

re-lock

all

Doors once more (

arming

the system again). 

Please note 

that most OEM systems will 

not

rearm the Alarm while the

Engine is running, but 

will

lock the Doors. 

Passive or Active Arming of the Starter Kill 

(Mode 1, Function 3: Option 1 – Passive with a 1-min. timeout – by default.) 

The Starter Kill can be programmed 

to be 

active

(

will not 

arm automatically) or 

passive

(

will

arm automatically). In Passive Mode, you can program it to 

arm automatically in 1 or 3 min.

To

disarm

the Starter Kill in Active or Passive Mode, the user must press and hold the 

UNLOCK

 button on the

Transmitter (or enable Valet Mode). The Parking Lights will flash twice. If the Door Locks option was installed, this will 
also unlock the Doors.

To

arm

the Starter Kill in Active or Passive Mode, the user must press and hold the

LOCK

 button on the Transmitter. 

The Parking Lights will flash once. (If the Door Locks option was installed, this will also lock the Doors). In Passive 
Mode, the system will automatically arm itself 1 or 3 minutes after the Engine is shut down. 

PS-2925

Installation Guide 

P. 9

Summary of Contents for PS-2925

Page 1: ...Installation Guide Table of Contents Table of Contents 1 Introduction 2 Included in the Kit 2 Before You Get Started 2 Installation Points to Remember 3 PS 2925 Features List 3 Plug ins 3 Harness Desc...

Page 2: ...button Remote Transmitters 1 R 1 Interconnect Cable 1 R 1 Receiver 1 Hood Pin switch 1 Plug in Valet Button 1 6 Pin Main Ignition Harness 1 5 Pin Secondary Harness 1 12 Pin Accessories Harness 1 Warn...

Page 3: ...ulse duration The Door pulse can be set from 7 10 sec to 4 sec and allow for double 1 4 sec unlock pulses Secure Lock and Arm This feature allows the Module to control certain OEM factory Alarm system...

Page 4: ...er Blower Motor F GREEN 5th Relay output 30 A This high current output can be used to power a second Ignition Accessories or Crank wire See Jumper settings on page 11 5 Pin Secondary Harness Wire Colo...

Page 5: ...l It can be connected to an external Starter Kill relay 8 ORANGE Parking Light output Negative Parking Light output 9 PURPLE External Trigger input This input will start the vehicle with a 1 second gr...

Page 6: ...Wiring Diagram P 6 Installation Guide PS 2925...

Page 7: ...OCK button twice within 3 seconds The Parking Lights will flash 5 times quickly 4 To exit close the Hood Note The L E D follows the Parking Lights in all modes The system can hold up to 4 Transmitters...

Page 8: ...ease the Valet Button The L E D will come ON Getting Out of Valet Mode 1 Turn the Ignition Key to the IGNITION ON RUN position 2 Press and release the Valet Button The L E D will go out Programming Op...

Page 9: ...is turned to the OFF position the Doors will automatically be unlocked Secure Lock Mode 1 Function 2 Option 1 OFF by default This feature allows the Module to control certain OEM factory Alarm systems...

Page 10: ...purpose of the Glow plug circuit on diesel vehicles is to pre heat the Combustion Chamber before the vehicle is started When a Remote Starter is installed on a diesel vehicle the Glow plug section of...

Page 11: ...the system is running under remote control the Starter Kill remains active This will provide Anti grind protection Caution When installing the Starter Kill it is extremely important that pin 86 be wir...

Page 12: ...cles must be equipped with an PS 2925 The Transmitter of the primary vehicle can control the Starter Kill system the Door Locks the remote car Starter and Trunk operation of the second vehicle The Tra...

Page 13: ...3 in from the roof 2 5 cm one inch below the tint strip is generally the best location Install the antenna as far as possible from radio antennas GPS OnStar or factory compasses Many factors may affe...

Page 14: ...ar signals 1 to 10 flashes followed by a pause followed by further flashes the system is playing back Event Logging Codes This occurs when the Hood Pin switch is pressed three times down up down up do...