 06

 

 

Functional Block/Sensor Part Diagram 

APT 3100 

 07

 

 

APT 3200 

Summary of Contents for 3100 A Series

Page 1: ...Quick Start Guide APT 3000 Series Autrol Corporation of America ...

Page 2: ...e trans mitters please read the full product manuals available under the download tab of www autroltransmitters com Additional instructional videos outlining programming and configuration functionalities can also be found on www autroltransmitters com First time users are encouraged to make use of these support resources made available at no cost online For additional technical support or advanced...

Page 3: ...hragm seals or cooling elements are recommended Set Units URL and LRL in menus 21 22 and 23 respectively See full menu tree at end of manual After installation of a 3100 D H Gor 3200 G always perform a Zero Trim menu 11 note this is not the same as Zeroing Ensure applied process to transmitter is zero beforeattempting Zero Trim Do not perform Zero Trim for 3100 A 3200 A absolute unless a true zero...

Page 4: ...06 Functional Block Sensor Part Diagram APT 3100 07 APT 3200 ...

Page 5: ...08 APT 3100 Dimensional Drawing 09 APT 3100 Exploded View ...

Page 6: ...10 APT 3100 MP Dimensional Drawing 11 APT 3100 MP Exploded View ...

Page 7: ...12 APT 3200 Dimensional Drawing 13 APT 3200 Exploded View ...

Page 8: ... Mode Output Up to 5 Digit Display Unit Error Menu Menu Option 15 The 5 digit LCD screen shows Up to 5 digits of measured value Error code Units Normal and Engineering Menu and Menu Option Indication of being in Normal or Engineering mode Indication of output being Linear or Square Root Indication of performing a Loop Test Indication of being in Multi Drop mode LCD Screen Rotation Unscrewing the t...

Page 9: ...16 LCD Screen Display Error Codes 17 ...

Page 10: ...self diagnostic routines are also designed to drive transmitter current output outside of the normal saturation values in case a fault mode is detected The transmitter will drive its current 4 20mA output low down or high up based on the position of the failure mode alarm jumper or DIP switch configured in line with NAMUR requirements 19 For Blind units using DIP switch on MCU board Fail Mode Sele...

Page 11: ... of the barrier into the max loop resistance calculations Max Loop Resistance Ω E 11 9 Vdc 0 022 mA Note for Standard 4 20mA output units operating at 11 9V is possible only with Zero load connected to transmitter analog output HART is not supported at this low of supply voltage input 17 5V is recommended as minimum drop across the transmitter for both HART and 250 Ohm loop re sistance loads 24V 3...

Page 12: ...gnal loop 2 HART Communication requires a loop resistance between 250 and 550 Ohm at 24 Vdc 3 Power Supply Voltage Range 12 to 45 Vdc Voltage Rating 24 Vdc 30 23 Connection Diagram For Low Voltage Transmitters Minimum operating input of 9V with no loading recommended 12V 48V maximum DC Power Input Power Supply Connection and Hang Jack Connection 1 5V Output Connection ...

Page 13: ...ding Recommended 24V minimum for pulse and 4 20mA 2 wire loops Pulse Specification Scaled Pulse A single pulse is output for a specified flow amount Pulse Width 10ms 50ms 100ms se lectable Duty Cycle 49 Pulse Second maximum Output Type Open Collector 30V 500mA maximum Relay or Impulse Counter Terminal Block Port 1 Terminal Block Port 2 DC Power Supply ...

Page 14: ...using to be rotated 90 counterclockwise 360 rotation possible however please take care that the sensor cable inside neck is not pinched or dam aged during re orientation 27 Lock Front Rear Covers Allen Screw provided on each side of Front and Rear Cover allows for locking the covers for tamper proofing Front Rear ...

Page 15: ...r proper grounding earth ground at designated points external or internal 29 Please provide for proper grounding earth ground at designated points external or internal Vent Drain Plugs Optional with F1 or F2 Code Standard with Bleed ...

Page 16: ... Zero and Span These magnetic push buttons are fully functioning see menu tree in following pages Re Ranging and Applying External PV Press Zero 5 sec When display shows ZR re lease the button Apply PV corresponding to de sired LRV 4mA setting Press Zero again Display will show Z or ZE if error occurs To adjust SPAN press SPAN button 5 sec When display shows SP re lease the button Apply PV corresp...

Page 17: ...e most current manual online for any specific updates on new firmware s and functionality included All available menus are divided into 4 primary sections 1 TRIM for trims loop test etc 2 SETUP for user configuration units range settings output damping etc 3 LCD for display resolution multi parameter display engineering mode 4 Device for reset password lock Hart Device ID etc Local Push Button Men...

Page 18: ...34 Fully Functioning Push Buttons Continued on next page 35 Fully Functioning Push Buttons Version 7 x and Higher ...

Page 19: ...36 Continued on next page 37 Version 7 x and Higher ...

Page 20: ...38 Continued on next page 39 Version 7 x and Higher ...

Page 21: ...40 41 Version 7 x and Higher ...

Page 22: ...42 Sub Menus Numeric Entry Sub Menu 43 Version 7 x and Higher Alpha Numeric Entry Sub Menu ...

Page 23: ......