- 39 -
6.2.1 Video Loss Setup
In Camera Setup, press ENTER to
call up Video Loss Setup of the
selected camera as shown when
the highlighted option is Video
Loss Settings.. of the camera to
setup. The Video Loss Setup
allows the administrator to define
how the system responds to the
detected video loss for the
camera.
The general operations are as
below:
Turn the Jog Dial or press
▲
▼
to select the items.
ESC
Press this button to escape from this screen, and return to Camera Setup display.
If the Save dialog is shown, press ENTER to exit and save, ESC to exit without
saving.
Following is a brief description for each item and its specific operations:
Duration –
response duration to define at most how long (in seconds) the Alarm
Out relay and the Buzzer will keep being triggered after video loss is detected for
this camera. However, the Alarm Out relay and the Buzzer will be reset
immediately once the camera returns to normal. Press +/- buttons to adjust the
value (3-60 seconds, discrete).
Pre-record –
to define how long before video loss is detected this camera shall
be intensively recorded at Pre-record IPS. Press +/- buttons to adjust the value
(0-60 seconds, discrete). Please note that the actual pre-record time may be
shorter than the value set if the total size of the pre-record pictures exceeds the
pre-record buffer size of the system.
Alarm Out –
to define which Alarm Output will be triggered when video loss of
this camera is detected. Press +/- buttons to select none (N/A) or one of the
Alarm Outputs (1-4).
Buzzer –
to activate the internal Buzzer or not when video loss of this camera is
detected. Press ENTER to check/uncheck this item. The default setting is “ˇ” -
checked.
Log –
to log to event logs or not. Press ENTER to check/uncheck this item.