background image

Modular Matrix Switcher 32x32

  13  

 www.av-box.ru 

3.3. Application 

MMX series has a good application in various occasions, such as radio & television, 
multi-media meeting room, big screen displaying, television education and command 
& control center etc. 

Summary of Contents for MMX3232

Page 1: ...www av box ru MMX3232 Modular Matrix Switcher 32x32 User Manual...

Page 2: ...trademark owner No part of this publication may be copied or reproduced without the prior written consent of AV BOX FCC Statement This equipment generates uses and can radiate radio frequency energy a...

Page 3: ...oisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you...

Page 4: ...2 2 2 4I DS 4O DS 6 2 2 3 4I HD 4O HD 6 2 2 4 4I VG 4O VG 7 2 2 5 4I VA 8 2 2 6 4I SD 4O SD 9 2 2 7 4I TP 4O TP 9 2 2 8 4I UH 4O UH 10 2 2 9 4I UF 4O UF 11 2 2 10 4I BT 4O BT 11 3 System Connection 1...

Page 5: ...n 25 5 1 Main Unit 25 5 2 Changeable Cards 26 5 2 1 4I DV 4O DV 26 5 2 2 4I DS 4O DS 26 5 2 3 4I HD 4O HD 27 5 2 4 4I VG 4O VG 27 5 2 5 4I VA 28 5 2 6 4I SD 4O SD 28 5 2 7 4I TP 4O TP 29 5 2 8 4I UH 4...

Page 6: ...xible design MMX3232 can be used for different project and tend to be an all in one solution It is the combo solution for multimedia conference rooms control rooms broadcasting rooms shopping center e...

Page 7: ...tputs for each channel SDI 4O TP 4 HDMI TP IR RS232 4O UH 4 HDMI PCM Audio 4O UF 4 Optical Fiber 4O BT 4 HDBT RS232 Audio 1 4 Package List 1 x MMX3232 1 x RS232 cable 4 x Plastic cushions 1 x IR remot...

Page 8: ...r input channels with green back light indicating ranges from 0 9 32 selectable channels in total OUTPUTS Buttons for output channels with green back light indicating ranges from 0 9 32 selectable cha...

Page 9: ...n total OUTPUTS Output signal card slots 8 in total Power switch Switch between AC110V and AC230V to access different power TCP IP Optional Used for TCP IP control port RS232 Serial control port conne...

Page 10: ...al can pass to output device through 4O DV or pass through other kinds of output cards 4O DV output card maximum four output signal output signals from 4I DV or other kinds of input cards Pin Layout o...

Page 11: ...gnal can come from 4I DS or from other kinds of input cards It supports off memory for resolution signal format HDCP compliant status Note When 4O DS works with input cards except 4I DS adjust the 4 i...

Page 12: ...ld 2 2 4 4I VG 4O VG VGA signal card Please check the specification from 5 2 4 Scale all inputs to 1080p Compatible with C Video YUV YC Factory preset function The bandwidth is up to 350MHz 3dB Suppor...

Page 13: ...g cable as shown below Connect with Component Video YPbPr Source Connect with Composite Video C VIDEO Source 2 2 5 4I VA VGA signal card Please check the specification from 5 2 5 Scale all inputs to 1...

Page 14: ...d maximum four output signal output signals from 4I SD or other kinds of input cards The BNC connector is shown as the figure below Sleeve Tip BNC Connector 2 2 7 4I TP 4O TP Twisted pair card HDMI DV...

Page 15: ...connected to the connector s metal shell to well share the grounding 2 2 8 4I UH 4O UH 4K HDMI signal card Please check the specification from 5 2 8 Support hot plug HDMI 1 4 HDCP 1 4 compliance Compa...

Page 16: ...or illuminates green when there is output signal Note Use the 4I UF 4O UF with optical fiber transmitter receiver 2 2 10 4I BT 4O BT Twisted pair card HDMI DVI extender Please check the specification...

Page 17: ...tions 1 System should be installed in a clean environment and has a prop temperature and humidity 2 All of the power switches plugs sockets and power cords should be insulated and safe 3 All devices s...

Page 18: ...er 32x32 13 www av box ru 3 3 Application MMX series has a good application in various occasions such as radio television multi media meeting room big screen displaying television education and comman...

Page 19: ...panel are counting from left to right top to bottom 6 The input delay time between two numbers of every input output channel must be less than 5 seconds otherwise the operation will be cancelled Examp...

Page 20: ...he same operations and commands with the control panel Press the buttons under below format Input Channel Switch Mode Output Channel Figure 4 1 Panel of the IR Remote Input channel buttons including 1...

Page 21: ...ers can control it by that computer To control the switcher users need to use RS232 control software 4 3 2 RS232 Communication Commands With this command system users are able to control and operate t...

Page 22: ...x1 to the output channel x2 Status x Inquire the input channel to the output channel x Status Inquire the input channel to the output channels one by one Save Y Save the present operation to the prese...

Page 23: ...rt number User definable command e g 0623 0911 Restore factory default Commands for Signal Cards 4I VA USER I x 0622 Set the signal of input channel x to VGA USER I x 0623 Set the signal of input chan...

Page 24: ...x Set the brightness of input x to xx xx 00 99 USER I x 03xx Set the contrast of input x to xx xx 00 99 USER I x 04xx Set the saturation of input x to xx xx 00 99 USER I x 05xx Set the sharpness of in...

Page 25: ...nal of input x to DVI 4O DS USER O x 0201 Set the input source of output x to YPbPr USER O x 0202 Set the input source of output x to VGA USER O x 0203 Set the input source of output x to C VIDEO USER...

Page 26: ...After running this command there will be no signals on all the outputs 4 Switch off the detail feedback command from the COM port MessageOff But it will leave the switch OK as the feedback when you sw...

Page 27: ...No 7 12 Recall the preset command Y Recall Y Example Recall5 to recall the preset command No 5 13 Clear the preset command Y Clear Y Example Clear5 to clear the preset command No 5 14 EDID management...

Page 28: ...Single PC Connect a computer to the TP port of the MMX3232 and set its IP address and gateway to the same IP section as the default IP of the MMX3232 192 168 0 178 Controlled by PC s in LAN The MMX323...

Page 29: ...router In the same LAN each PC is able to control the MMX3232 asynchronously 4 4 2 TCP IP Settings Step1 Connect the TCP IP port of the MMX3232 to Ethernet port of PC with twisted pair Step2 Set the P...

Page 30: ...change the serial port b Set the port number to 4001 unique other numbers are unavailable c Press the button Apply on present page to save your settings Step6 Select the tab reset device then your se...

Page 31: ...DC Supports Extended Display Identification Data EDID and Display Data Channel DDC data using DVI and HDMI standards EDID and DDC signals are actively buffered HDCP Compliant with HDCP using DVI and H...

Page 32: ...y 5nS 1nS Switching Speed 200ns Max Crosstalk 50dB 5MHz EDID and DDC Supports Extended Display Identification Data EDID and Display Data Channel DDC data using DVI and HDMI standards EDID and DDC sign...

Page 33: ...S video composite video Switching Speed 200ns Max Crosstalk 50dB 5MHz 5 2 6 4I SD 4O SD Input Output Input 4 SDI Output 4 SDI Input Connector Female BNC Output Connector Female BNC Input Level 0 8Vp p...

Page 34: ...MHz 100M Return Loss 30dB 5KHz THD 0 005 1KHz Min Max Level 0 3V 1 45Vp p HDMI Standard Support HDMI1 4a and HDCP Differential Phase Error 10 135MHz_100M 5 2 8 4I UH 4O UH Input Video Input Audio Inpu...

Page 35: ...r Optical Output 4 Fiber Optical Input Connector SPF Fiber Optical Connector Output Connector SPF Fiber Optical Connector Fiber Type Multi mode Single mode Fiber Type Multi mode Single mode General Da...

Page 36: ...put Impedance 75 Output Impedance 100 Differential Frequency Response 20Hz 20K Hz Control Part Control Signal 4 RS232 Control Connector 3 pin pluggable terminal block Protocol TCP IP General Gain 0dB...

Page 37: ...thorized dealer for repairing IR remote does not work Run out of battery Change for another battery IR remote is broken Send it to authorized dealer for repairing POWER indicator doesn t work or no re...

Page 38: ...g Cannot control the device by front panel buttons while can control it through RS232 port The front panel buttons are locked Send command 50605 to unlock the front panel buttons Cannot control the de...

Page 39: ...y expiration Factory applied serial number has been altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our spec...

Reviews: